Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS
Siemens DCA HbA1c Reagent Kit for DCA Vantage Analyzer

Siemens DCA HbA1c Reagent Kit for DCA Vantage Analyzer

Product Details:

  • Accuracy Certified traceable to IFCC/NGSP standards
  • Feature Rapid results (~6 mins), minimal sample, barcoded reagents
  • Set Contains 10 reagent cartridges, instructions, code chip
  • Portable No, for use with DCA Vantage Analyzer
  • Power Not applicable (used in cartridge format with analyzer)
  • Application Clinical testing of HbA1c in blood samples
  • Condition New, Sealed
  • Click to View more
X

Siemens DCA HbA1c Reagent Kit for DCA Vantage Analyzer Price And Quantity

Siemens DCA HbA1c Reagent Kit for DCA Vantage Analyzer Product Specifications

  • Clinical laboratories, diabetes clinics
  • Immunoassay Latex agglutination inhibition methodology
  • Yes, real-time analysis on DCA Vantage
  • IVD grade reagent chemicals, Plastic cartridges
  • HbA1c Reagent Kit for DCA Vantage Analyzer
  • White with standard Siemens labeling
  • Rapid results (~6 mins), minimal sample, barcoded reagents
  • 10 reagent cartridges, instructions, code chip
  • No, for use with DCA Vantage Analyzer
  • Certified traceable to IFCC/NGSP standards
  • New, Sealed
  • Rectangular cartridges
  • Not applicable (used in cartridge format with analyzer)
  • Clinical testing of HbA1c in blood samples
  • 10 tests/kit
  • Kit packaging approx. 19 cm x 12 cm x 5 cm
  • For quantitative determination of HbA1c in blood
  • Quantitative in-vitro diagnostic for HbA1c
  • No
  • Semi-automated (used with DCA Vantage Analyzer)
  • Store refrigerated at 28C, do not freeze
  • Single-use cartridges
  • High precision, minimal sample volume, fast results
  • Automated assay kit
  • Single-use cartridges
  • DCA Vantage Analyzer
  • Capillary or venous whole blood
  • Typically 1218 months from manufacture
  • Batch and lot number on packaging
  • Does not contain hazardous substances
  • 1 L
  • Approximately 6 minutes
  • Barcoded cartridge for lot-specific calibration

Siemens DCA HbA1c Reagent Kit for DCA Vantage Analyzer Trade Information

  • 1000 Unit Per Day
  • Week

Product Description

Brand Siemens
Sample Type Whole Blood
Pack Size 10T
CAT No 10698915

The DCA HbA1c test kit gives primary-care professionals the tools to fight the diabetes epidemic on the front lines. Early detection and tight glycemic control help mitigate the serious conditions that accompany diabetes: heart and kidney disease, limb neuropathy, retinopathy, and stroke. More importantly, patients identified as being at risk can stop or reverse disease progression through lifestyle adjustments and/or pharmacological treatment.



Fast and Accurate HbA1c Testing

With result times of approximately six minutes and certified traceability to IFCC/NGSP standards, the Siemens DCA HbA1c Reagent Kit ensures rapid, precise quantification of glycated hemoglobin. Its advanced immunoassay technology supports high accuracy for clinicians monitoring glycemic control.


Minimal Sample Volume Required

The kit requires only 1 L of capillary or venous whole blood, making sample collection simple and minimally invasive. This low volume supports patient comfort while maintaining reliable test performance in busy clinical environments.


Convenient Lot-Specific Calibration

Each kit includes a barcoded cartridge enabling seamless lot-specific calibration with the DCA Vantage Analyzer. The included code chip ensures traceability, reducing errors and enhancing analytic consistency from batch to batch.

FAQ's of Siemens DCA HbA1c Reagent Kit for DCA Vantage Analyzer:


Q: How is the Siemens DCA HbA1c Reagent Kit used with the DCA Vantage Analyzer?

A: The reagent kit is designed for use exclusively with the DCA Vantage Analyzer. Follow the included instructions to load a single-use cartridge and the code chip for calibration. Add 1 L of whole blood sample as directed; the analyzer then runs an automated, real-time quantitative HbA1c assay.

Q: What type of blood sample is required for testing with this kit?

A: The kit is intended for use with capillary or venous whole blood samples. Only 1 L of blood is needed per test, which can be easily obtained via fingerstick or venipuncture, offering flexibility for different clinical settings.

Q: When should the Siemens DCA HbA1c Reagent Kit be replaced or reordered?

A: Since each kit contains ten single-use cartridges, replacement is necessary after ten tests. Kits should also be reordered if the expiration date, typically 12-18 months from manufacture, is reached or if cartridges have been exposed to improper storage conditions.

Q: Where should the reagent kit be stored for optimal performance?

A: The reagent kit must be stored refrigerated at 2-8C and should never be frozen. Proper storage ensures reagent stability and maintains reliable test results throughout its shelf life.

Q: What is the process for calibrating the DCA Vantage Analyzer with this kit?

A: Calibration is performed through a barcoded cartridge and an included code chip, specific to each reagent lot. Insert the chip into the analyzer as instructed before running tests to ensure accurate, lot-specific calibration and traceability.

Q: What are the benefits of using the Siemens DCA HbA1c Reagent Kit?

A: Benefits include rapid results (approximately six minutes), high precision, minimal blood volume requirements, certified traceability, and ease of use with the semi-automated DCA Vantage Analyzer. The disposable cartridges ensure safety and convenience for clinical staff and patients.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical POCT' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.