Product Description
| Brand | Abbott |
| Stent Diameter (mm) | 8.0 |
| Stent Length (mm) | 20, 30 40 |
| CAT No | 1011340-20, 1011340-30, 1011340-40 |
The RX Acculink Carotid Stent System, used in conjunction with the Abbott Vascular embolic protection system, is indicated for the treatment of patients at high and standard risk for adverse events from carotid endarterectomy who require carotid revascularization.
Advanced Stent Design for Enhanced ConformabilityThe RX Acculink Carotid Stent System features an open cell design crafted from nitinol, delivering outstanding flexibility and vessel conformability. The stent adapts effortlessly to the natural contours of carotid arteries, optimizing patient safety by minimizing stress on vessel walls. Radiopaque marker bands support clear visualization during fluoroscopy, aiding precise placement.
Efficient and Accurate Delivery SystemEquipped with a 135 cm usable catheter, the RX Rapid Exchange Delivery System allows fast and simple stent deployment. Its compatibility with 5F guiding sheaths offers versatility, and the low-profile, atraumatic tip helps reduce the risk of vessel injury. Enhanced radiopacity facilitates real-time monitoring for accurate stent deployment.
Sterility, Safety, and PortabilityManufactured sterile using ethylene oxide, the Acculink Stent System ensures safety in clinical settings. Lightweight and disposable, it provides convenience for both hospital and ambulatory use, while its single-use nature enhances infection control. No power source is needed, ensuring silent, fully manual operation suitable for a range of procedural environments.
FAQ's of Abbott RX Acculink Carotid Stent System:
Q: How does the open cell design of the Abbott RX Acculink Stent benefit carotid artery treatments?
A: The open cell design enhances the stent's flexibility and conformability, allowing it to adapt precisely to the vessel's natural shape. This flexibility improves apposition to vessel walls, reducing the risk of complications and optimizing blood flow restoration in carotid artery revascularization.
Q: What is the delivery process for the RX Acculink Carotid Stent System?
A: The stent system utilizes a Rapid Exchange (RX) Delivery System with a 135 cm catheter. The system is manually operated, compatible with 5F guiding sheaths, and deployed under fluoroscopy using radiopaque marker bands for accurate placement. The atraumatic tip further minimizes vessel trauma during delivery.
Q: When should the RX Acculink Stent System be used?
A: This stent system is indicated for the treatment of carotid atherosclerotic disease in patients where revascularization is required to restore blood flow and prevent stroke. Usage should be determined by a qualified healthcare provider after thorough patient evaluation.
Q: Where can the RX Acculink Carotid Stent System be utilized in clinical practice?
A: The system is approved for use in hospital settings, operating rooms, and interventional suites by trained medical professionals. It is CE Marked and FDA approved for specific regions. Always verify regional regulatory clearance before use.
Q: What are the benefits of radiopacity and marker bands during stent placement?
A: Enhanced radiopacity and precise marker bands allow interventionalists to clearly visualize stent position under fluoroscopy. This significantly increases the accuracy of placement, minimizing repositioning and ensuring optimal outcomes with fewer complications.
Q: How should the Abbott RX Acculink Carotid Stent System be stored before use?
A: The stent system should be stored in a cool, dry environment, away from direct sunlight, according to manufacturer's specifications. Proper storage ensures device sterility and optimal performance when used.
Q: Is the Abbott RX Acculink Carotid Stent System reusable or single-use?
A: This stent system is designed for single-use only and must be disposed of after one procedure to maintain patient safety and prevent infection risk.