Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS    Call Me Free
Abbott i-STAT EC8+ Cartridge

Abbott i-STAT EC8+ Cartridge

Product Details:

  • Operating Type Manual, for use with i-STAT analyzer
  • Condition New
  • Storage Instructions Store at 2-8C, do not freeze
  • Function Measures multiple blood chemistry and electrolyte parameters
  • Real-Time Operation Yes
  • Accuracy Meets CLIA and CE standards
  • Technology Electrochemical biosensor, microfluidic
  • Click to View more
X

Abbott i-STAT EC8+ Cartridge Price And Quantity

  • Single-Use Disposable
  • Refrigerated
  • For professional in-vitro diagnostic use only
  • Integrated internal calibration
  • Requires i-STAT system LCD display
  • Whole blood
  • Up to expiration date on packaging, usually 612 months
  • For use with Abbott i-STAT portable clinical analyzers
  • Digital data via i-STAT system
  • Approximately 95 L
  • 23 minutes per sample
  • Sodium, Potassium, Chloride, Total CO2, Ionized Calcium, Glucose, Blood Urea Nitrogen (BUN), Creatinine, Hematocrit

Abbott i-STAT EC8+ Cartridge Product Specifications

  • Blood Gas and Chemistry Analyzer Cartridge
  • Yes
  • Hospitals, ICUs, ambulances, clinics
  • One blood sample per cartridge
  • 25 cartridges per box (typical packaging)
  • Multiparameter testing in minutes
  • Standard for i-STAT system compatibility
  • Point-of-care blood testing, emergency, critical care, lab diagnostics
  • Single-use, disposable, sealed unit
  • Approx. 7.2 x 2.1 x 1 cm per cartridge
  • Silent Operation
  • White
  • In-vitro diagnostic for analyzing multiple blood parameters
  • No
  • Medical-grade plastic
  • Not applicable (powered by i-STAT system)
  • Single-patient, cartridge-based
  • Rectangular cartridge
  • Electrochemical biosensor, microfluidic
  • Yes
  • Meets CLIA and CE standards
  • Measures multiple blood chemistry and electrolyte parameters
  • Store at 2-8C, do not freeze
  • New
  • Manual, for use with i-STAT analyzer
  • Single-Use Disposable
  • Refrigerated
  • For professional in-vitro diagnostic use only
  • Integrated internal calibration
  • Requires i-STAT system LCD display
  • Whole blood
  • Up to expiration date on packaging, usually 612 months
  • For use with Abbott i-STAT portable clinical analyzers
  • Digital data via i-STAT system
  • Approximately 95 L
  • 23 minutes per sample
  • Sodium, Potassium, Chloride, Total CO2, Ionized Calcium, Glucose, Blood Urea Nitrogen (BUN), Creatinine, Hematocrit

Abbott i-STAT EC8+ Cartridge Trade Information

  • 1000 Unit Per Day
  • Week

Product Description

Brand Abbott
Sample Type Whole Blood
Pack Size 25T
CAT No 03P79-25

i-STAT EC8+ Cartridge providing lab-quality results fast when every minute counts.Cartridge containing tests for electrolytes, chemistries, blood gases, hematocrit & hemoglobin.



Comprehensive Multiparameter Testing

Designed for rapid analysis, the Abbott i-STAT EC8+ Cartridge enables healthcare professionals to assess a panel of critical blood chemistry and electrolyte parameters from a single whole blood sample. Reliable and efficient, this cartridge streamlines patient assessment in a range of clinical environments, including hospitals, ICUs, ambulances, and outpatient clinics.


Simple Operation and Fast Results

This disposable cartridge operates with the Abbott i-STAT analyzer's LCD interface, requiring minimal manual handling. Within just 2-3 minutes, users receive accurate, real-time results, facilitating immediate clinical decision-making. The sealed design, silent operation, and integrated calibration support user confidence and optimal workflow.


Portable and Reliable for Point-of-Care

The compact size and user-friendly format allow for easy transport and use wherever urgent blood analysis is necessary. The cartridges maintain stability under refrigerated conditions and are packaged for convenience, with each box containing 25 individually sealed units suitable for various clinical and emergency scenarios.

FAQ's of Abbott i-STAT EC8+ Cartridge:


Q: How do I use the Abbott i-STAT EC8+ Cartridge with the analyzer?

A: To use the cartridge, insert approximately 95 L of whole blood into the cartridge's sample port, then load the cartridge into the Abbott i-STAT analyzer. The system's LCD display guides the process, and results are available in 2-3 minutes.

Q: What parameters can the EC8+ Cartridge measure in a single test?

A: The EC8+ Cartridge measures sodium, potassium, chloride, total CO2, ionized calcium, glucose, blood urea nitrogen (BUN), creatinine, and hematocrit in one sample, providing a comprehensive panel for clinical assessment.

Q: When should the EC8+ Cartridge be used for patient testing?

A: This cartridge is suited for immediate, point-of-care blood analysis in critical care, emergency, and laboratory settings when rapid and reliable results are needed to inform treatment decisions.

Q: Where should I store the EC8+ Cartridges to ensure quality?

A: Store EC8+ Cartridges in a refrigerator at 2-8C. Do not freeze. Maintain storage conditions as indicated on the packaging to ensure validity up to the expiration date.

Q: What is the process for disposing of used cartridges?

A: After use, each cartridge is single-use and should be disposed of according to your facility's standard protocols for medical waste. The materials are sealed to ensure safe handling.

Q: What are the main benefits of using the Abbott i-STAT EC8+ Cartridge?

A: Benefits include rapid, multiparameter testing at the point of care, portability, accuracy meeting regulatory standards (CLIA and CE), minimal blood volume required, and integrated internal calibration for reliable results.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical POCT' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.