Product Description
| Brand |
Snibe |
| Sample Type |
Serum |
| Pack Size |
100T |
| CAT No. |
130211004M |
| Application |
Biochemical |
The kit has been designed for the quantitative determination of 25-OH Vitamin D in human serum. The method can be used for samples over the range of 0-150ng/ml. The test has to be performed on the MAGLUMI chemiluminescence immunoassay (CLIA) fully auto analyzer (Including MAGLUMI 1000, MAGLUMI 2000, MAGLUMI 2000 Plus and new developed models).
High Efficiency and AutomationThe MAGLUMI 25-OH Vitamin D reagent kit is optimized for use in automated CLIA analyzers, delivering up to 180 tests per hour depending on the specific platform. This high capacity is especially beneficial for busy clinical laboratories, significantly improving workflow and throughput for vitamin D measurement.
Accurate and Reliable ResultsUtilizing a competitive chemiluminescence immunoassay principle, the kit achieves precise quantification of both 25-OH Vitamin D2 and D3. With an intra- and inter-assay CV 10% and a measurement range from 4.0 to 120 ng/mL, laboratories can rely on stable, reproducible results that aid confident clinical decisions.
Ready-to-Use and User-FriendlyAll reagents are supplied in a liquid, stable format requiring no reconstitution, supporting convenient setup and maintenance. The kit includes all necessary components, such as microparticles, conjugate, substrates, calibrators, and controls, emphasizing ease of use and ensuring that laboratories can focus on efficient vitamin D testing.
FAQs of Snibe MAGLUMI 25-OH Vitamin D (CLIA):
Q: How does the MAGLUMI 25-OH Vitamin D (CLIA) reagent kit operate?
A: The kit works by a competitive chemiluminescence immunoassay (CLIA) method. It is designed exclusively for use on compatible automated MAGLUMI analyzers, where serum or plasma samples are processed to quantitatively measure 25-OH Vitamin D.
Q: What types of samples can be used with this kit?
A: The assay accommodates both human serum and plasma samples, providing laboratories flexibility in handling different sample matrices as required in clinical diagnostics.
Q: When should calibration be performed for accurate results?
A: Calibration intervals should follow the recommendations provided by the MAGLUMI analyzer and as specified in the product literature or labeling. Regular calibration with the included calibrators ensures sustained accuracy.
Q: Where is the MAGLUMI 25-OH Vitamin D kit intended to be utilized?
A: This kit is intended for hospital laboratories and clinical diagnostic labs equipped with compatible MAGLUMI CLIA analyzers, and is not suitable for point-of-care or home use.
Q: What is the process involved in conducting the test?
A: Laboratories load samples and the ready-to-use reagents into the MAGLUMI CLIA analyzer. The automated system then performs the CLIA assay, yielding results in approximately 30 minutes per sample.
Q: What are the key benefits of using this vitamin D detection kit?
A: Key advantages include high throughput, strong accuracy, broad measuring range, and liquid-stable reagents for easy handling. The kit also ensures reliable reproducibility and complies with CE IVD regulations.
Q: How should the reagent kit be stored and handled?
A: All kit components should be stored at 28C, ensuring they are never frozen. Proper storage preserves reagent integrity and consistent test performance throughout the 12-month shelf life.