Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS    Call Me Free
FUJIFILM FUJI DRI-CHEM SLIDE UA-P III FUJIFILM FUJI DRI-CHEM SLIDE UA-P III FUJIFILM FUJI DRI-CHEM SLIDE UA-P III FUJIFILM FUJI DRI-CHEM SLIDE UA-P III FUJIFILM FUJI DRI-CHEM SLIDE UA-P III
FUJIFILM FUJI DRI-CHEM SLIDE UA-P III
FUJIFILM FUJI DRI-CHEM SLIDE UA-P III FUJIFILM FUJI DRI-CHEM SLIDE UA-P III FUJIFILM FUJI DRI-CHEM SLIDE UA-P III FUJIFILM FUJI DRI-CHEM SLIDE UA-P III

FUJIFILM FUJI DRI-CHEM SLIDE UA-P III

Product Details:

  • Usage Type Single Use
  • Instruments Type Compatible with FUJIFILM DRI-CHEM Analyzers
  • Features Ready-to-use, Calibrated, Easy Handling, Accurate Results
  • Shelf Life Up to 24 Months (when unopened)
  • Storage Instructions Store at 2-8C in a dry place
  • Measurement Range 0.520.0 mg/dL (Uric Acid)
  • Function Measurement of Uric Acid (UA) in Serum/Plasma
  • Click to View more
X

FUJIFILM FUJI DRI-CHEM SLIDE UA-P III Price And Quantity

FUJIFILM FUJI DRI-CHEM SLIDE UA-P III Product Specifications

  • White
  • Measurement of Uric Acid (UA) in Serum/Plasma
  • Clinically Validated for Uric Acid measurement
  • Standard Cartridge Size (refer to analyzer spec)
  • Diagnostic Reagent Slide
  • Automated / Manual (with Compatible Analyzer)
  • No
  • Compatible with FUJIFILM DRI-CHEM Analyzers
  • Ready-to-use, Calibrated, Easy Handling, Accurate Results
  • New
  • Plastic, Chemical Coated Substrate
  • Single Use
  • Lightweight (Typically <20g per slide)
  • Dry Chemistry
  • 0.520.0 mg/dL (Uric Acid)
  • Veterinary and Clinical Diagnostic
  • Store at 2-8C in a dry place
  • Yes
  • Not Required for Slide Alone
  • Up to 24 Months (when unopened)
  • Silent Operation
  • Yes

FUJIFILM FUJI DRI-CHEM SLIDE UA-P III Trade Information

  • 100 Unit Per Week
  • 7 Days

Product Description

Brand FUJIFILM
Sample Type Serum/ Plasma
Pack Size 24T
CAT No 15809700
Application Uric Acid Concentration

Fujifilm DRI-CHEM SLIDE Colorimetric method slide. Enzymes, General chemistry, and Immunology. This multilayered slide is composed of dry chemical ingredients needed for the reaction and other functional materials. It quantifies enzymes and chemicals using colorimetric method.



Accurate and Rapid Uric Acid Measurement

Harnessing advanced enzymatic colorimetric technology, the UA-P III slide provides clinicians and veterinarians with quick and reliable uric acid readings from serum or plasma. Precalibrated and ready-to-use, it streamlines the diagnostic workflow by delivering results within minutes when paired with select FUJIFILM DRI-CHEM analyzers.


Convenient Design with Superior Storage Stability

Each UA-P III slide is individually sealed for optimal freshness and integrity, ensuring accurate diagnostics whenever needed. With a shelf life up to 24 months when stored at 2-8C in a dry location, these portable slides support flexibility in clinical or veterinary laboratories without compromising result quality.


Simple Workflow and Broad Compatibility

Engineered to fit seamlessly into the FUJIFILM FDC analyzer series, the slides require minimal sample volume and are suitable for both manual and automated operations. Their user-friendly handling, silent operation, and robust result accuracy make them a preferred solution for busy diagnostic environments.

FAQ's of FUJIFILM FUJI DRI-CHEM SLIDE UA-P III:


Q: How is the FUJI DRI-CHEM SLIDE UA-P III used for uric acid measurement?

A: The UA-P III slide is used by applying a 10 L serum or plasma sample onto the slide, which is then inserted into a compatible FUJIFILM DRI-CHEM analyzer. The analyzer processes the sample using an enzymatic colorimetric method and delivers uric acid concentration results within minutes.

Q: What are the storage requirements for these slides?

A: To maintain accuracy and shelf life, store the slides at 2-8C in a dry environment. Each slide is individually sealed to protect from moisture and contamination until use.

Q: When should the expiration date on the slide pack be checked?

A: Always check the printed expiration date before each use. Using expired slides may lead to inaccurate or unreliable results.

Q: Where can the SLIDE UA-P III be used?

A: These slides are suitable for use in both veterinary and clinical diagnostic settings, including hospitals, clinics, and laboratory environments across India.

Q: What are the benefits of using the UA-P III slide?

A: The main benefits include rapid results, minimal sample volume, high sensitivity and specificity, easy handling, and compatibility with FUJIFILM FDC analyzers. The slides are designed for accuracy and efficiency in single-use diagnostic applications.

Q: How do I avoid contamination while using these slides?

A: Use clean technique when handling the slides and ensure that only compatible analyzers are used. Do not touch the sample area, and always keep the slide sealed until ready for immediate use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical Reagents' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.