Product Description
Brand Mindray
Sample Type Serum
Pack Size 2 x 50T, 2 x 100T
CAT No 10500566000, 10500567700
Application Immuno-Assay
Ourchemiluminescence immunoassay reagentshave been specially developed to work with Mindray's CL series automatic chemiluminescence immunoassay analyzers to make a complete system, offering high reliability and accuracy. Mindray uses liquid, ready-to-use reagents which come in two packages, 50 tests and 100 tests, to suit customers with different requirements.
Accurate and Efficient BNP DetectionLeveraging advanced chemiluminescence immunoassay technology, the Mindray BNP kit delivers highly accurate readings within a measurement range of 5 - 5000 pg/mL. Its streamlined two-step procedure and direct chemiluminescent measurement enable rapid turnaround, supporting timely clinical decision-making. Ideal for high-throughput needs, it maintains a calibration interval of 28 days, reducing downtime and maintenance requirements.
User-Friendly and Reliable DesignWith automatic real-time operation, silent performance, and a lightweight, portable form factor, this kit seamlessly integrates into diverse lab settings. All necessary quality controls are included, and its compatibility with CL-900i and CL-1200i instruments ensures ease of use for clinicians and laboratory personnel. Designed for clinical reliability, it is intended strictly for in vitro diagnostic applications.
FAQ's of Mindray B-type natriuretic peptide (CLIA):
Q: How does the Mindray BNP Diagnostic Reagent Kit measure B-type natriuretic peptide levels?
A: The kit utilizes a two-step sandwich chemiluminescence immunoassay (CLIA) to directly measure BNP concentrations in human serum or plasma. This process uses specific antibodies and chemiluminescent detection to ensure highly sensitive and accurate results.
Q: What is the minimum sample volume required and which sample types are suitable for this assay?
A: A minimum sample volume of 50 L is required. The assay is compatible with both human serum and plasma samples, offering flexibility in clinical and laboratory environments.
Q: When should calibration and quality control be performed with this kit?
A: Calibration is recommended every 28 days, as per the kit's instructions. Both internal and external quality control reagents are included for routine checks and to ensure ongoing assay reliability.
Q: Where can the Mindray BNP Diagnostic Kit be used, and which platforms is it compatible with?
A: This kit is intended for clinical and diagnostic laboratory use. It is specifically designed for use with Mindray CL-900i and CL-1200i chemiluminescence platforms for precise cardiac marker detection.
Q: What is the assay time and measurement range for BNP detection?
A: The assay provides results in approximately 30 minutes, with a measurement range spanning from 5 to 5000 pg/mL, enabling both early detection and monitoring of cardiac function.
Q: How should the reagent kit be stored to maintain its shelf life and performance?
A: Store the kit at a temperature between 2-8C and protect it from direct sunlight. Under these conditions, it maintains a shelf life of up to 12 months.
Q: What are the main benefits of using the Mindray BNP Chemiluminescence Kit?
A: This kit delivers rapid, accurate, and reliable quantitative BNP results, supports high-throughput operations, requires minimal sample volume, and integrates ease of use with automated, silent operation-providing significant advantages for cardiac risk assessment in clinical practice.