Snibe MAGLUMI hs-Troponin I (CLIA) Snibe MAGLUMI hs-Troponin I (CLIA) Snibe MAGLUMI hs-Troponin I (CLIA)
Snibe MAGLUMI hs-Troponin I (CLIA)
Snibe MAGLUMI hs-Troponin I (CLIA) Snibe MAGLUMI hs-Troponin I (CLIA)

Snibe MAGLUMI hs-Troponin I (CLIA)

Product Details:

  • Function Cardiac biomarker detection
  • Accuracy Within manufacturers specified CV <10%
  • Features High sensitivity, Fast turnaround time, Wide linear range, Reliable performance
  • Usage Type In-vitro Diagnostic (IVD) reagent
  • Measurement Range 0.150 ng/mL
  • Instruments Type MAGLUMI Series Automated Immunoassay Analyzer
  • Shelf Life 12 months
  • Click to View more
X

Snibe MAGLUMI hs-Troponin I (CLIA) Price And Quantity

Snibe MAGLUMI hs-Troponin I (CLIA) Product Specifications

  • No (for use with laboratory analyzer)
  • Within manufacturers specified CV <10%
  • High sensitivity, Fast turnaround time, Wide linear range, Reliable performance
  • Yes
  • Cardiac biomarker detection
  • Diagnostic Reagent, Microbeads, Antibodies, Buffer Solution
  • Immunoassay Analyzer Reagent Kit
  • In-vitro Diagnostic (IVD) reagent
  • 2~8C, avoid freezing
  • Automated
  • MAGLUMI Series Automated Immunoassay Analyzer
  • No
  • 12 months
  • 0.150 ng/mL
  • Not Applicable (for reagent kit; compatible with MAGLUMI automated analyzers)
  • Quantitative determination of S-Troponin I in human serum or plasma
  • Colorless (Solution)
  • Chemiluminescence Immunoassay (CLIA)
  • New

Product Description

Brand Snibe
Sample Type Serum
Pack Size 100T
CAT No. 13020609M
Application Infection

The kit has been designed for the quantitative determination of Troponin I (high sensitive) in human serum. The method can be used for samples over the range of 0-50ng/ml. The test has to be performed on the MAGLUMI chemiluminescence immunoassay (CLIA) fully auto analyzer (Including MAGLUMI 1000, MAGLUMI 2000, MAGLUMI 2000 Plus and new developed models).



Precision Cardiac Biomarker Analysis

Snibe MAGLUMI S-Troponin I enables laboratories to provide accurate, real-time cardiac biomarker detection for rapid clinical decision-making. Its advanced chemiluminescence technology and automated process ensure dependable results for patient management in acute cardiovascular emergencies.


User-Friendly and Reliable Performance

Designed with convenience in mind, the kit comes as a ready-to-use liquid format, requiring no elaborate preparation. Automated operation on the MAGLUMI analyzers ensures ease of use, minimal hands-on time, and consistent performance within a 12-month shelf life.


Adaptable to Laboratory Workflows

The reagent kit is suitable for diverse laboratory environments across India, serving dealers, suppliers, and healthcare facilities. Its compatibility with all MAGLUMI analyzers and standard storage conditions (2-8C) makes it accessible and flexible for varying testing volumes.

FAQ's of Snibe MAGLUMI S-Troponin I (CLIA):


Q: How does the Snibe MAGLUMI S-Troponin I (CLIA) detect Troponin I in samples?

A: The kit uses a two-site sandwich chemiluminescence immunoassay, which specifically binds S-Troponin I in human serum or plasma, allowing quantitative detection through MAGLUMI automated immunoassay analyzers.

Q: What is the recommended calibration schedule for this test kit?

A: Calibration should be performed according to analyzer guidelines, typically every 28 days or more frequently as indicated by quality control results.

Q: Where is the Snibe MAGLUMI S-Troponin I kit typically used?

A: This reagent kit is intended for use in clinical laboratories equipped with MAGLUMI Series Automated Immunoassay Analyzers. It is not portable and is suitable for in-vitro diagnostic use in hospitals and diagnostic centers.

Q: When can test results be expected after sample loading?

A: Results are typically available in about 18 minutes per test cycle when running on a MAGLUMI platform.

Q: What are the benefits of using this kit for acute myocardial infarction management?

A: It provides high sensitivity and reliability, enabling early detection of cardiac events. Fast turnaround times support prompt clinical assessment and improved patient outcomes.

Q: How should the reagent kit be stored to maintain stability?

A: The reagents should be stored at 2-8C, avoiding freezing, to ensure optimal shelf life and assay performance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical CLIA' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.