Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS
Mindray Dehyro-epi-androsterone sulfate (CLIA) Mindray Dehyro-epi-androsterone sulfate (CLIA) Mindray Dehyro-epi-androsterone sulfate (CLIA)
Mindray Dehyro-epi-androsterone sulfate (CLIA)
Mindray Dehyro-epi-androsterone sulfate (CLIA) Mindray Dehyro-epi-androsterone sulfate (CLIA)

Mindray Dehyro-epi-androsterone sulfate (CLIA)

Product Details:

  • Function Detection and quantification of DHEA-S in human serum/plasma
  • Usage Type Single-use, in vitro diagnostic
  • Features High sensitivity, specificity, ready-to-use reagents, compatible with Mindray CLIA analyzers
  • Storage Instructions 28C, do not freeze
  • Measurement Range 0.11000 g/dL (depends on analyzer specifications)
  • Shelf Life 12 months from date of manufacture
  • Instruments Type Compatible with Mindray CL-Series (CL-1000i, CL-2000i)
  • Click to View more
X

Mindray Dehyro-epi-androsterone sulfate (CLIA) Price And Quantity

Mindray Dehyro-epi-androsterone sulfate (CLIA) Product Specifications

  • High sensitivity, specificity, ready-to-use reagents, compatible with Mindray CLIA analyzers
  • Not Applicable (reagent kit)
  • 28C, do not freeze
  • No
  • Chemiluminescence Immunoassay (CLIA)
  • CLIA (Chemiluminescence Immunoassay) Reagent
  • High (as per manufacturers quality standards)
  • Not Applicable (reagent kit)
  • No
  • Yes
  • Quantitative measurement of Dehydroepiandrosterone sulfate (DHEA-S) in human serum or plasma
  • Single-use, in vitro diagnostic
  • 12 months from date of manufacture
  • Liquid reagent kit (chemically stabilized) for in vitro diagnostic use
  • Compatible with Mindray CL-Series (CL-1000i, CL-2000i)
  • Automated, analyzer-based
  • New
  • Detection and quantification of DHEA-S in human serum/plasma
  • 0.11000 g/dL (depends on analyzer specifications)
  • Clear to light yellow (reagent appearance)

Product Description

Brand Mindray

Sample Type Serum

Pack Size 2 x 50T, 2 x 100T

CAT No 10500567400, 10500569100

Application Immuno-Assay

Ourchemiluminescence immunoassay reagentshave been specially developed to work with Mindray's CL series automatic chemiluminescence immunoassay analyzers to make a complete system, offering high reliability and accuracy. Mindray uses liquid, ready-to-use reagents which come in two packages, 50 tests and 100 tests, to suit customers with different requirements.



High Sensitivity and Accurate Performance

Utilizing advanced Chemiluminescence Immunoassay (CLIA) technology, this reagent kit is engineered for excellent sensitivity and specificity in measuring DHEA-S concentrations. The multi-point calibration and quality control components guarantee precise quantification, making it reliable for clinical decisions.


Ready-to-Use Convenience and Stability

The Mindray DHEA-S CLIA kit offers liquid, ready-to-use reagents that facilitate streamlined workflow in clinical laboratories. Each vial remains stable for up to 28 days on the analyzer, ensuring consistency and minimal reagent wastage during routine use.


Designed for Clinical Versatility

Compatible with Mindray CL-Series chemiluminescence analyzers, the kit is well-suited to hospital and laboratory settings. It supports quantitative DHEA-S detection in both serum and plasma, with rapid assay times and manufacturer-traceable lots to ensure quality compliance.

FAQ's of Mindray Dehyro-epi-androsterone sulfate (CLIA):


Q: How should the Mindray DHEA-S CLIA reagent kit be stored to maintain reagent stability?

A: The reagent kit should be stored at temperatures between 2-8C and must not be frozen. When stored appropriately, the open vial stability on compatible analyzers is maintained for up to 28 days.

Q: What is the process for running a DHEA-S test using this kit on Mindray CL-Series analyzers?

A: First, prepare the patient sample (serum or plasma), calibrator, and control as specified. Load the reagents, samples, calibrators, and controls onto the compatible Mindray CLIA analyzer. The assay is fully automated; results are typically available within 20 minutes.

Q: What are the benefits of using this kit for hospitals and clinical laboratories?

A: This kit provides high sensitivity and specificity for DHEA-S quantification. It offers convenience with ready-to-use reagents, rapid assay time, built-in quality control, and reliable lot traceability, supporting efficient and accurate clinical workflow.

Q: When is calibration required for this assay, and what is included in the kit for this purpose?

A: A multi-point calibration is required as per analyzer instructions, especially when opening a new reagent lot or as recommended by laboratory protocols. The necessary specific calibrator is included in the kit for consistent and reliable calibration.

Q: Where can this CLIA reagent kit be used and who are the intended users?

A: The kit is designed for use in hospitals, clinical laboratories, and diagnostic centers. Intended users are trained healthcare professionals such as laboratory technicians and clinical pathologists.

Q: What are the usage instructions regarding the compatibility and sample requirements for this reagent kit?

A: The kit is compatible exclusively with Mindray CL-Series chemiluminescence analyzers (e.g., CL-1000i, CL-2000i). It is validated for use with human serum or plasma samples collected under standard clinical procedures.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical Reagents' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.