Product Details:

  • Storage Instructions 28C, avoid freezing
  • Shelf Life 12 months from manufacturing date
  • Usage Type Laboratory diagnostic use only
  • Features High sensitivity, specific detection, ready-to-use reagents, for use with Snibe MAGLUMI analyzers
  • Accuracy <10% CV (within run and total precision)
  • Instruments Type For use with Snibe MAGLUMI Series (fully automated immunoassay analyzers)
  • Measurement Range 0.237.77 ng/dL
  • Click to View more
X

Snibe MAGLUMI FT4 (CLIA) Price And Quantity

Snibe MAGLUMI FT4 (CLIA) Product Specifications

  • Instrument powered (external, not part of kit)
  • Measures FT4 levels in serum/plasma
  • In vitro quantitative determination of Free Thyroxine (FT4) in human serum or plasma
  • 12 months from manufacturing date
  • Laboratory diagnostic use only
  • 0.237.77 ng/dL
  • Reagent Kit (plastic vials, sealed packaging)
  • 28C, avoid freezing
  • For use with Snibe MAGLUMI Series (fully automated immunoassay analyzers)
  • Kit box: 18 x 14 x 7 cm (approx.)
  • White with printed label
  • Approx. 0.5 kg (entire kit)
  • No
  • <10% CV (within run and total precision)
  • FT4 Chemiluminescent Immunoassay (CLIA) Kit
  • Automated
  • High sensitivity, specific detection, ready-to-use reagents, for use with Snibe MAGLUMI analyzers
  • CLIA (Chemiluminescence Immunoassay)
  • New
  • Yes (reagent box is portable)
  • Yes
  • Clinical laboratories, hospitals, diagnostic centers
  • Sandwich immunoassay using two monoclonal antibodies for FT4
  • Human serum or plasma (EDTA, heparin, citrate)
  • FT4 is a sensitive marker of thyroid function, used for detecting thyroid disorders
  • Microparticles, enzyme conjugate, calibrators, buffer, instructions for use
  • 100 tests
  • 10 L
  • Every 4 weeks or as per instrument protocol
  • Exclusively for Snibe MAGLUMI automated platforms

Product Description

Brand Snibe
Sample Type Serum
Pack Size 100T
CAT No. 130253004M
Application Thyroid Marker

The kit has been designed for the quantitative determination of Free Thyroxine (FT4) in human serum. The method can be used for samples over the range of 1.0-120.0 pg/ml. The test has to be performed on the Fully-auto chemiluminescence immunoassay (CLIA) analyzer MAGLUMI (Including Maglumi 600,Maglumi 1000,Maglumi 1000 Plus, Maglumi 2000,Maglumi 2000 Plus,Maglumi 3000 and Maglumi 4000).



Precise FT4 Measurement for Thyroid Diagnostics

The Snibe MAGLUMI FT4 (CLIA) kit provides accurate, real-time measurement of Free Thyroxine (FT4) in human serum or plasma. With a measurement range of 0.23-7.77 ng/dL and high sensitivity, it is ideal for detecting and monitoring thyroid function in clinical laboratory settings. Ready-to-use reagents and fully automated operation streamline workflow for laboratory professionals.


Advanced CLIA Technology for Reliable Results

Employing chemiluminescent immunoassay (CLIA) technology, this FT4 kit utilizes a sandwich principle with two monoclonal antibodies for specific detection. The automated process on Snibe MAGLUMI analyzers ensures consistent performance and minimal manual intervention, maintaining accuracy and reproducibility across runs.


User-Centric Design and Convenient Operation

This FT4 kit is user-friendly, featuring pre-measured reagents and a compact, portable kit box. With a sample volume requirement of just 10 L and a straightforward calibration interval of every four weeks, laboratory personnel can achieve efficient, reliable, and high-throughput testing with minimal waste.

FAQ's of Snibe MAGLUMI FT4 (CLIA):


Q: How does the Snibe MAGLUMI FT4 (CLIA) kit detect Free Thyroxine?

A: The kit uses a sandwich immunoassay principle, employing two highly specific monoclonal antibodies and chemiluminescent detection to quantitatively measure Free Thyroxine (FT4) in serum or plasma samples.

Q: What types of samples are compatible with this assay?

A: The kit is designed for use with human serum or plasma samples collected in EDTA, heparin, or citrate tubes, offering flexibility in sample preparation for clinical laboratories.

Q: When should kit calibration be performed?

A: Calibration should be conducted every four weeks or according to the specific protocols recommended by your Snibe MAGLUMI analyzer to ensure consistent accuracy of FT4 measurements.

Q: Where can the Snibe MAGLUMI FT4 kit be used?

A: This kit is intended for laboratory diagnostic use in hospitals, clinical laboratories, and diagnostic centers equipped with Snibe MAGLUMI Series automated immunoassay analyzers.

Q: What is the procedure for running a test with this kit?

A: Simply load the kit's reagents onto the Snibe MAGLUMI analyzer, add 10 L of serum or plasma from the patient sample, and follow the instrument prompts. Results are generated automatically with no manual intervention required.

Q: What are the key benefits of using this FT4 kit?

A: Benefits include high accuracy (<10% CV), ready-to-use reagents, automated operation, and a sensitive measurement range, making it ideal for detecting and monitoring thyroid disorders quickly and reliably.

Q: How should the kit be stored to maintain reagent integrity?

A: Store the kit at 2-8C and avoid freezing. Proper storage ensures the reagents remain stable and effective throughout the 12-month shelf life from the manufacturing date.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical CLIA' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.