Product Details:

  • Material High-quality plastic & metal body
  • Condition New
  • Technology Microplate ELISA Reader (Absorbance technology)
  • Portable No
  • Wall Mounted No
  • Light Source Halogen lamp, 6V/10W
  • Display Type LCD Display
  • Click to View more
X

Erba Mannheim LisaScan EM Price And Quantity

  • Approx. 5 seconds per well
  • Automatic and manual options
  • USB port, RS-232 serial port
  • Ambient to 40°C operating
  • 400-700 nm (4 filters provided: 405, 450, 492, 630 nm)
  • 96 wells (8x12) standard microplates
  • External printer supported

Erba Mannheim LisaScan EM Product Specifications

  • 0.001 Absorbance units
  • LCD Display
  • Microplate incubator & washer compatibility
  • New
  • Microplate ELISA Reader (Absorbance technology)
  • Photodiode sensor system
  • Compact Desktop Size
  • PC
  • Approx. 40 VA
  • Low
  • Approx. 8 kg
  • No
  • Automatic
  • USB and RS-232 serial port
  • Stores up to 100 test results
  • 100-240V AC, 50/60Hz
  • Yes
  • White and Blue
  • Windows-based LisaScan software supplied
  • Visible Light 400-700 nm
  • Halogen lamp, 6V/10W
  • Absorbance measurement at selectable wavelengths
  • Used for ELISA test processing
  • High-quality plastic & metal body
  • AC mains
  • No
  • Approx. 5 seconds per well
  • Automatic and manual options
  • USB port, RS-232 serial port
  • Ambient to 40°C operating
  • 400-700 nm (4 filters provided: 405, 450, 492, 630 nm)
  • 96 wells (8x12) standard microplates
  • External printer supported

Product Description

Brand Erba Mannheim
Model LisaScan EM
Capacity 96 Wells & 4 Filter, 96 Wells & 6 Filter
CAT No 103133, 111689
Application Immunology

The LisaScan EM offers objective and standard reading of ELISA microplates with interpretation. Automated ELISA microplate reader.



Efficient ELISA Processing

The LisaScan EM is built for swift and reliable ELISA test processing, supporting a wide range of routine and specialized immunoassays. With real-time operation, fast reading speeds, and compatibility with standard microplates, laboratories can process samples with heightened efficiency. Data synchronization via USB or RS-232 ensures seamless information transfer, while integrated automatic and manual calibration protects accuracy.


Advanced Optical Performance

Featuring a powerful halogen lamp and photodiode sensor system, LisaScan EM provides absorbance measurements at selectable wavelengths, enhancing assay flexibility. Its resolution of 0.001 absorbance units and precise wavelength filters guarantee dependable results, while temperature control up to 40C supports consistent experimental conditions across varied protocols.

FAQ's of Erba Mannheim LisaScan EM:


Q: How does the LisaScan EM support seamless ELISA workflow integration?

A: The LisaScan EM integrates smoothly with laboratory workflows by supporting standard 96-well microplates, automatic and manual calibration, fast data transfer through USB and RS-232, and compatibility with microplate incubators and washers. Its Windows-based software allows easy result management and synchronization with PCs.

Q: What is the recommended application of the LisaScan EM microplate reader?

A: This device is primarily designed for ELISA test processing, suitable for diverse applications in clinical diagnostics and life science research, where absorbance-based measurement is required.

Q: When should automatic versus manual calibration be used?

A: Automatic calibration is ideal for routine operations, ensuring the reader maintains accuracy with minimal intervention. Manual calibration is recommended when specific assay adjustments or troubleshooting are needed, providing precise control over calibration parameters.

Q: Where can the LisaScan EM be installed within a laboratory?

A: Its compact, desktop-sized design allows placement on any suitable laboratory bench. It is not wall-mountable and requires access to AC mains power and a connection to a PC or printer for full operation.

Q: What is the process for transferring and managing ELISA test results?

A: Results are stored in the reader's internal memory, which can hold up to 100 test results. Data can be transferred to a PC using the USB or RS-232 ports, and printed via an external printer. The Windows-based LisaScan software facilitates easy data management and analysis.

Q: How does using the LisaScan EM benefit laboratory operations?

A: LisaScan EM enhances lab productivity by offering rapid, reliable, and accurate absorbance readings. Its compatibility with microplate automation accessories, ease of calibration, and flexible connectivity streamline the ELISA testing process, leading to efficient workflows and consistent results.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical Analyzer' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.