Product Description
Brand Boditech
Sample Type Serum/ Plasma/ WB
Pack Size 24T
CAT No SMFP-8
Biomarker Hormone Function
This test helps select and diagnose mammary gland development, infertility treatment and pituitary diseases by quantifying blood PRL.
Advanced Fluorescence Immunoassay TechnologyLeveraging sensitive FIA technology, the AFIAS Prolactin Analyzer ensures precise quantification of prolactin across a wide range of human samples. This rapid testing method provides clinicians with accurate, real-time results, streamlining diagnostic workflows and enabling timely patient management.
Streamlined Operation and Fast ResultsWith a semi-automatic design and minimal sample volume requirement, the AFIAS PRL test kit empowers professionals to achieve results in just 12 minutes. Intuitive LCD touch controls and embedded calibration guarantee consistent performance and ease of use, even in busy clinical settings.
Enhancing Laboratory ProductivityThe AFIAS-6 model supports up to 36 tests per hour and offers extensive data storage for up to 5,000 test results. Its compact, portable design and versatile connectivity (USB, LAN, RS232) make integration seamless, while maintaining low noise and energy efficiency for optimal laboratory operation.
FAQ's of Boditech AFIAS Prolactin (PRL):
Q: How does the Boditech AFIAS Prolactin (PRL) analyzer operate?
A: The analyzer utilizes a fluorescence immunoassay (FIA) technique to quantitatively measure prolactin levels in human serum, plasma, or whole blood. It requires only 50 L of sample and delivers results in approximately 12 minutes via a simple, semi-automatic process on an intuitive LCD touch screen.
Q: What benefits does the AFIAS PRL system provide in clinical settings?
A: Key benefits include fast turnaround time, high sensitivity, low sample volume requirement, automatic lot-specific calibration, extensive data storage, ease of operation, robust connectivity, and reliability approved by CE-IVD marking. These features enhance workflow efficiency and diagnostic accuracy.
Q: When should the AFIAS Prolactin test be used?
A: This test is intended for professional use in clinical laboratories or hospitals to quantitatively assess prolactin levels in human blood. It is valuable in diagnosing conditions such as pituitary disorders, infertility, and abnormal lactation.
Q: Where can the AFIAS PRL analyzer be installed and used?
A: The system is portable and suitable for use in clinical laboratories or hospital settings. It should be kept on a stable surface within the specified temperature (10-35C) and humidity (20-80% RH) ranges, and stored away from direct sunlight at 2-8C when not in use.
Q: What is the process for running a Prolactin test using this kit?
A: Simply load the 50 L sample into the reagent cartridge, place it into the AFIAS analyzer, and follow on-screen instructions. The embedded auto-calibration feature ensures accuracy with each lot, and results are displayed on the screen within about 12 minutes.
Q: How is data stored and accessed on the AFIAS PRL analyzer?
A: The analyzer can store up to 5,000 test results. Data can be accessed, managed, and transferred via USB, LAN, or RS232 ports, supporting efficient record-keeping and integration into laboratory information systems.