Product Description
| Brand | Roche |
| Sample Type | Whole Blood |
| Pack Size | 5T |
| CAT No | 11621947196 |
Qualitative detection of troponin in anticoagulated (EDTA or heparin) venous whole blood. Positive result from a threshold (cut-off) of 100 ng/L. At room temperature (15?25 C), the unopened pouch is stable for up to 4 weeks but not beyond the expiration date.
Fast and Reliable Cardiac Marker DetectionWith a turnaround time of 15 minutes, the Roche Troponin T Sensitive Test supports prompt clinical decisions in suspected acute myocardial events. Its high accuracy provides confidence to healthcare professionals while its easy visual reading-by simple identification of red/pink lines-reduces risk of interpretive errors.
User-Friendly and Portable DesignThis test requires only 100 L of sample, is packaged for single use, and is both maintenance and noise free. The lightweight kit is portable, so it can be used in emergencies, outpatient settings, or at the patient's bedside. No additional instruments or power are needed, streamlining operation and expanding its practical utility.
FAQ's of Roche Roche cardiac Troponin T sensitive test (visual):
Q: How is the Roche Cardiac Troponin T Sensitive Test performed?
A: To perform the test, add 100 L of whole blood, serum, or plasma to the test device sample well, then add the provided buffer. Wait 15 minutes for red/pink lines to appear in the window, indicating results. Visual interpretation determines whether Troponin T is present (positive) or not (negative).
Q: What is the main benefit of using this test in clinical practice?
A: The main benefit is rapid and reliable detection of cardiac Troponin T, supporting timely diagnosis of myocardial injury. Its >98% accuracy, ease of use, and portability make it ideal for emergency or point-of-care situations.
Q: When should this test be used?
A: This test is intended for professional use when there is clinical suspicion of cardiac injury, such as in cases of chest pain or suspected acute myocardial infarction. It is useful for urgent screening and triage in hospitals or clinics.
Q: Where can the Roche Troponin T Sensitive Test be utilized?
A: The portable, manual design allows for use in a range of clinical environments-emergency rooms, outpatient departments, ambulances, or bedside locations-without requiring specialized equipment or electricity.
Q: What is the measurement threshold and readout method for this test?
A: The test is qualitative, with a detection threshold of approximately 40 pg/mL of cardiac Troponin T. Results are interpreted visually by the presence or absence of colored lines in the cassette window.
Q: How should the test kits be stored and handled?
A: Store kits at temperatures between 2C and 30C; do not freeze. Each kit has a shelf life of 24 months from the manufacturing date and tests should be used only once. Ensure components remain sealed until use.
Q: Is any equipment or power source required for operation?
A: No equipment or power source is needed for this manual, visual test. Operation is entirely manual, providing flexibility and ease of use in settings without laboratory infrastructure.