Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS
Abbott CHOLESTECH LDX LIPID PROFILE CASSETTES

Abbott CHOLESTECH LDX LIPID PROFILE CASSETTES

Product Details:

  • Capacity Single test per cassette
  • Accuracy Correlates with laboratory reference assays
  • Dimension (L*W*H) Standardized for LDX analyzer; compact design
  • Color White
  • Set Contains Box of multiple test cassettes
  • Attributes Disposable, single-use
  • Operation Mode Manual
  • Click to View more
X

Abbott CHOLESTECH LDX LIPID PROFILE CASSETTES Price And Quantity

Abbott CHOLESTECH LDX LIPID PROFILE CASSETTES Product Specifications

  • White
  • Box of multiple test cassettes
  • Standardized for LDX analyzer; compact design
  • Single test per cassette
  • Correlates with laboratory reference assays
  • Disposable, single-use
  • Manual
  • Lipid Profile Cassette
  • Rectangular cassette
  • Not applicable (analyzer powered separately)
  • Fast results, high reliability
  • Quantitative measurement of lipid parameters (cholesterol, HDL, triglycerides)
  • Yes
  • To determine lipid panel values
  • Enzymatic colorimetric assay
  • High-grade medical plastic
  • Store at 2-8C, do not freeze
  • Yes
  • Lipid profile testing
  • Silent
  • New, sterile packaging
  • In clinical laboratories, physician offices, and point-of-care settings
  • Manual insertion into analyzer
  • Custom-fit for Abbott Cholestech LDX
  • No
  • No
  • Up to expiration date indicated on the package
  • 10-90% (non-condensing)
  • Approximately 5 minutes per test
  • Total Cholesterol, HDL Cholesterol, Triglycerides, calculated LDL Cholesterol, TC/HDL ratio
  • Integrated control features for procedural accuracy
  • 15-30°C (during use)
  • 35-40 µL capillary or venous whole blood, serum, or plasma
  • Non-reusable; dispose after single use
  • 1 box
  • Clearly printed on individual cassette packaging
  • Designed exclusively for Abbott Cholestech LDX System

Abbott CHOLESTECH LDX LIPID PROFILE CASSETTES Trade Information

  • 1000 Unit Per Day
  • Week

Product Description

Brand Abbott
Sample Type Whole Blood
Pack Size 10T
CAT No 97989

The Lipid Profile cassette measures total cholesterol (TC), a measure of the total amount of cholesterol in the blood, high density lipoprotein (HDL) cholesterol ("good cholesterol) and triglycerides or TRG (fatty acids and glycerol that circulate in the blood and are stored as body fat). Lipid Profile also calculates the TC/HDL ratio, non-HDL cholesterol, and estimates the level of LDL cholesterol ("bad cholesterol). For use with the Cholestech LDX System



Fast and Reliable Lipid Testing

Experience rapid lipid panel analysis with Abbott CHOLESTECH LDX Lipid Profile Cassettes. Each cassette delivers comprehensive lipid results within approximately five minutes, enabling timely clinical decisions. The advanced enzymatic colorimetric technology ensures correlated accuracy with standard laboratory assays, making them indispensable in physician offices, outpatient clinics, and point-of-care situations.


Designed for Ease of Use and Compatibility

These cassettes are engineered exclusively for the Abbott Cholestech LDX System, guaranteeing optimal compatibility and precise results. Manual operation and standardized sizing simplify integration into your workflow, while single-use disposability ensures both sterility and convenience. The clear labeling and expiry date on each package promote dependable usage.

FAQ's of Abbott CHOLESTECH LDX LIPID PROFILE CASSETTES:


Q: How do I use the Abbott CHOLESTECH LDX Lipid Profile Cassette in the analyzer?

A: To use, collect 35-40 L of the required sample (whole blood, serum, or plasma), insert the cassette manually into the Cholestech LDX System, and follow the analyzer prompts. Results will be generated within about five minutes.

Q: What parameters can the cassette measure during a lipid profile test?

A: The cassette quantitatively measures total cholesterol, HDL cholesterol, triglycerides, calculated LDL cholesterol, and the TC/HDL ratio using enzymatic colorimetric technology.

Q: When should I dispose of a used cassette?

A: Each cassette is designed for single-use only and must be immediately discarded after one test to maintain sterility and prevent cross-contamination.

Q: Where should the cassettes be stored to maintain their efficacy?

A: Store the cassettes at 2-8C as indicated on the packaging. Do not freeze and ensure the expiry date is observed for reliable results.

Q: What are the benefits of using these cassettes in point-of-care settings?

A: They provide fast, accurate lipid panel results, enabling clinicians to make timely decisions and enhance patient care in outpatient or clinical environments.

Q: Is any power required to operate the cassette itself?

A: No power is needed for the cassette; it is powered by manual insertion into the separately powered Abbott Cholestech LDX System analyzer.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical POCT' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.