Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS
Awareness Technology ChemWell Fusion- 4800 PC Controlled EIA and CLIA Combination Analyzer Awareness Technology ChemWell Fusion- 4800 PC Controlled EIA and CLIA Combination Analyzer Awareness Technology ChemWell Fusion- 4800 PC Controlled EIA and CLIA Combination Analyzer
Awareness Technology ChemWell Fusion- 4800 PC Controlled EIA and CLIA Combination Analyzer
Awareness Technology ChemWell Fusion- 4800 PC Controlled EIA and CLIA Combination Analyzer Awareness Technology ChemWell Fusion- 4800 PC Controlled EIA and CLIA Combination Analyzer

Awareness Technology ChemWell Fusion- 4800 PC Controlled EIA and CLIA Combination Analyzer

Product Details:

X

Awareness Technology ChemWell Fusion- 4800 PC Controlled EIA and CLIA Combination Analyzer Price And Quantity

Awareness Technology ChemWell Fusion- 4800 PC Controlled EIA and CLIA Combination Analyzer Trade Information

  • 100 Unit Per Week
  • 7 Days

Product Description

Brand Awareness Technology
Model ChemWell Fusion- 4800
Capacity 96 Wells
CAT No 4800
Application Molecular

ChemWell Fusion is an open system adaptable to ELISA and glow-type CLIA applications.ChemWell Fusion provides pre-dilution options, mixing, variable incubation, plate washing,total pipetting functions, the software times the addition of conjugates, substrates andstop solutions while monitoring sample and reagent volumes as well as other parameters toassure precise, reliable results.



Advanced Dual-Mode Immunoassay Capabilities

The ChemWell Fusion-4800 combines EIA and CLIA technologies, enabling laboratories to run both photometric and chemiluminescent assays from a single automated platform. Its high-throughput capacity and flexible plate handling streamline complex workflows and reduce turnaround times for diverse clinical applications.


Precision Pipetting and Reliable Results

Equipped with a precision 1-8 channel pipetting robot and advanced liquid level/clot detection, the Fusion-4800 minimizes manual intervention and maximizes reproducibility. Automated calibration, error alarms, and programmable reaction volumes ensure every sample is processed with accuracy and consistency.


Intuitive Control and Seamless Integration

Operated via an external PC and the ChemWell Fusion software, the analyzer offers a multilingual interface, real-time data processing, and connectivity with Laboratory Information Systems. Automated maintenance protocols and user-friendly design make routine operation straightforward for operators at every experience level.

FAQ's of Awareness Technology ChemWell Fusion- 4800 PC Controlled EIA and CLIA Combination Analyzer:


Q: How does the ChemWell Fusion-4800 optimize assay throughput in clinical laboratories?

A: The ChemWell Fusion-4800 processes up to 192 tests per hour or four microplates per run, thanks to its automated plate handling and high-speed precision pipetting. This allows laboratories to complete large batches efficiently, enhancing productivity and reducing turnaround time for results.

Q: What sample types and detection methods are supported by this analyzer?

A: The system accepts serum, plasma, and other body fluids as samples. It supports both photometric (EIA) and chemiluminescent (CLIA) detection, making it adaptable to a wide range of immunoassay protocols.

Q: When should I perform maintenance, and is it complicated?

A: Routine maintenance is simplified by the analyzer's automated protocols, which guide users through regular cleaning and performance checks. Prompts are provided by the software based on usage, ensuring smooth, reliable operation without requiring specialized technical training.

Q: Where is data from the ChemWell Fusion-4800 stored and how can it be accessed?

A: All test data is securely stored on the external PC connected to the analyzer. Information can be accessed via the ChemWell Fusion software and is easily transferrable to Laboratory Information Systems through USB or Ethernet connections.

Q: What is the process for calibrating the instrument for different assays?

A: Calibration can be performed automatically or manually through the ChemWell Fusion software. The analyzer streamlines this process by prompting users and logging calibration data for traceability and easy retrieval for quality control reviews.

Q: How does the device enhance laboratory safety during operation?

A: The Fusion-4800 is fitted with liquid level sensors, clot detection, and error alarms to protect samples and reagents, minimizing risk of cross-contamination or operational errors. These features help ensure the integrity of every test run.

Q: What benefits does the dual-mode (EIA/CLIA) functionality offer to a clinical lab?

A: By uniting EIA and CLIA capabilities in a single system, labs can consolidate testing processes, save space, and expand their menu of immunoassays. This flexibility translates to higher throughput and adaptability for a variety of diagnostic needs.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical Analyzer' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.