Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS
Snibe MAGLUMI EBV EA IgA (CLIA) Snibe MAGLUMI EBV EA IgA (CLIA) Snibe MAGLUMI EBV EA IgA (CLIA)
Snibe MAGLUMI EBV EA IgA (CLIA)
Snibe MAGLUMI EBV EA IgA (CLIA) Snibe MAGLUMI EBV EA IgA (CLIA)

Snibe MAGLUMI EBV EA IgA (CLIA)

Product Details:

  • Instruments Type Compatible with Snibe MAGLUMI analyzers
  • Frequency Single test per sample
  • Measurement Range Qualitative detection of EBV EA IgA
  • Usage Type In vitro diagnostic use
  • Shelf Life 12 months from manufacturing
  • Storage Instructions Store at 28C, protected from light
  • Features High sensitivity and specificity; Ready-to-use reagents; Calibrators and controls included
  • Click to View more
X

Snibe MAGLUMI EBV EA IgA (CLIA) Price And Quantity

Snibe MAGLUMI EBV EA IgA (CLIA) Product Specifications

  • Automated
  • High sensitivity and specificity; Ready-to-use reagents; Calibrators and controls included
  • Depends on analyzer
  • New
  • 98% (based on manufacturer data)
  • No
  • White/Blue kit vials
  • Yes
  • Detection of EBV early antigen IgA antibodies
  • Depends on analyzer
  • Immunoassay Reagent Kit
  • Qualitative detection of EBV EA IgA
  • Diagnostic grade chemicals (for CLIA)
  • Kit packaging dimensions vary
  • Requires compatible immunoassay analyzer
  • Yes
  • Compatible with Snibe MAGLUMI analyzers
  • Single test per sample
  • Approx 0.51 kg per kit
  • Chemiluminescent Immunoassay (CLIA)
  • Negligible
  • Store at 28C, protected from light
  • In vitro diagnostic use
  • 12 months from manufacturing
  • Detection of Epstein-Barr Virus (EBV) Early Antigen IgA in human serum or plasma
  • Results interpreted via MAGLUMI analyzer system software
  • Provided with each kit for traceability
  • Reagent vials, calibrators, controls, buffer solution, instructions for use
  • Human serum or plasma
  • Internal calibrators and quality controls included
  • 1 kit
  • High (suitable for batch or random access testing)
  • Yes, for reagent identification
  • As specified in manufacturers instructions
  • Typically 100 tests per kit

Product Description

Brand Snibe
Sample Type Serum
Pack Size 100T
CAT No. 130265002M
Application Infection

The kit has been designed for the qualitative determination of EBV EA IgA in human serum. The test has to be performed on the Fully-auto chemiluminescence immunoassay (CLIA) analyzer MAGLUMI (Including Maglumi 600,Maglumi 1000,Maglumi 1000 Plus, Maglumi 2000,Maglumi 2000 Plus,Maglumi 3000 and Maglumi 4000).



Efficient EBV Detection

The MAGLUMI EBV EA IgA kit is engineered for timely and precise qualitative detection of EBV early antigen IgA antibodies in clinical laboratories. By combining robust reagent performance with advanced CLIA technology, this kit significantly improves diagnostic accuracy in detecting acute or reactivated EBV infections.


Comprehensive Kit Components

Each kit contains ready-to-use reagent vials, calibrators, controls, buffer solutions, and user-friendly instructions, enabling reliable results and straightforward implementation. The inclusion of internal calibrators and quality controls enhances result consistency and traceability, while the integrated barcode system supports efficient reagent management.


Automated and High Throughput

The kit is designed for automated use on Snibe MAGLUMI analyzers, supporting both batch and random access testing. High throughput capability makes it suitable for busy diagnostic settings requiring rapid turnaround and high accuracy. Its portability and compact packaging ease integration into diverse laboratory environments.

FAQ's of Snibe MAGLUMI EBV EA IgA (CLIA):


Q: How is the Snibe MAGLUMI EBV EA IgA (CLIA) kit used in a laboratory setting?

A: The kit is intended for use with Snibe MAGLUMI analyzers and is employed for detecting Epstein-Barr Virus (EBV) Early Antigen IgA antibodies in human serum or plasma. Samples are prepared and loaded onto the analyzer alongside the kit reagents, with results automatically interpreted by the system's software.

Q: What components are included in each kit and how do they contribute to the testing process?

A: Each kit provides diagnostic-grade reagent vials, calibrators, controls, a buffer solution, and detailed instructions. The included calibrators and controls ensure the test's accuracy and precision, while the barcode supports efficient reagent identification and traceability.

Q: When should this kit be considered for diagnostic testing?

A: This kit is suitable when qualitative detection of EBV EA IgA is clinically indicated-commonly in cases suspected of recent or reactivated EBV infection. Ideal for use in routine and specialized diagnostic laboratories handling high volumes or batch testing.

Q: Where can the kit be stored, and what are the recommended conditions?

A: The kit should be stored at 2-8C, protected from light, to preserve reagent stability and ensure a 12-month shelf life from manufacturing. Proper storage is essential for optimal test performance.

Q: What is the process for interpreting results with this kit?

A: Results are interpreted directly via the MAGLUMI analyzer system software, following the test run. The software provides qualitative results based on the chemiluminescent signals, ensuring accuracy through internal calibrators and controls.

Q: Which benefits does the kit provide over standard EBV antibody detection methods?

A: The kit offers high sensitivity and specificity, minimal manual handling, automated processing, and consistent results with robust quality control. This reduces error rates and turnaround times compared to manual or less automated approaches.

Q: Who can supply the Snibe MAGLUMI EBV EA IgA (CLIA) kit in India?

A: Authorized dealers, distributors, exporters, manufacturers, suppliers, traders, and wholesalers across India offer the kit, ensuring reliable access for clinical laboratories nationwide.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical CLIA' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.