Product Details:

  • Capacity Data log up to 1000 data points
  • Usage Measurement of pH, ion concentration, mV, ORP, and temperature
  • Dimension (L*W*H) 220 x 175 x 78 mm
  • Application Water analysis, research laboratories, industry laboratories, environmental testing
  • Voltage 100240 V AC, 50/60 Hz
  • Product Type pH/ISE Benchtop Meter
  • Color White and Blue
  • Click to View more
X

Thermo Scientific Orion Star A214 pH/ISE Benchtop Meter Price And Quantity

Thermo Scientific Orion Star A214 pH/ISE Benchtop Meter Product Specifications

  • White and Blue
  • pH/ISE Benchtop Meter
  • 1.2 kg
  • Laboratory Instrument
  • Universal AC adapter
  • Plastic housing
  • Touch keypad, LCD display
  • 220 x 175 x 78 mm
  • Water analysis, research laboratories, industry laboratories, environmental testing
  • 100240 V AC, 50/60 Hz
  • Data log up to 1000 data points
  • Measurement of pH, ion concentration, mV, ORP, and temperature

Product Description

Brand                   Thermo Fisher Scientific

Model                   Orion

Capacity              -2.000 to 20.000 pH

CAT No                 STARA2140

Application          Detection Monitor



Record accurate and reliable pH, ion concentration, mV, ORP and temperature measurements with the Thermo Scientific Orion Star A214 pH and ISE Benchtop Meter. This meter is ideal for a wide range of applications and advanced pH or ion analysis in the lab. Perform up to 5 point pH and ISE calibrations, log up to 2000 data point sets with time/date stamp and easily transfer calibration and data logs via USB or RS232 to a printer or computer with free downloadable Orion Star Com software. Use the included electrode stand to easily place sensors in samples and simplify storage to minimize breakage



Precision Measurement and Versatility

The Orion Star A214 delivers accurate and reliable results for pH, mV, ORP, ISE, and temperature measurements. Its multi-resolution settings and broad measurement ranges make it suitable for various laboratory and industrial applications, enabling high-performance water quality analysis and research flexibility.


User-Friendly Features for Laboratories

Designed with a backlit, multi-line LCD screen and touch keypad, this instrument ensures ease of operation in laboratory environments. The adjustable electrode stand adds convenience during sample handling, while its robust plastic housing protects internal components against laboratory spills and wear.


Comprehensive Data Management and Compliance

The benchtop meter can store up to 1000 data points in non-volatile memory. GLP compliance and the ability to transfer data via USB or RS232 interfaces make it ideal for labs requiring stringent quality assurance and seamless integration into data analysis workflows.

FAQ's of Thermo Scientific Orion Star A214 pH/ISE Benchtop Meter:


Q: How does the Orion Star A214 ensure accurate measurement of pH and ion concentration?

A: The Orion Star A214 offers up to five calibration points for pH, automatic temperature compensation, and high-resolution capability (up to 0.001 for pH, 0.1 mV for mV). This precision, combined with robust calibration protocols, provides reliable and repeatable results for critical laboratory analyses.

Q: What measurement applications is the Orion Star A214 suitable for?

A: This benchtop meter is widely used for water analysis, environmental testing, and research within both academic and industrial laboratory settings. Its versatility allows precise measurement of pH, ion concentration (ISE), mV, ORP, and temperature across diverse samples.

Q: When should I calibrate the meter for optimal results?

A: Calibration should be performed before each series of measurements or when accuracy is paramount, especially when switching between different sample types. The meter supports up to five calibration points, ensuring optimal instrument performance across the full pH range.

Q: Where can stored measurement data be accessed or exported from the device?

A: All measurement data is securely stored in the meter's non-volatile memory (up to 1000 data sets). For further analysis or record-keeping, data can be quickly exported via the integrated USB or RS232 interfaces to compatible external devices or computers.

Q: What is the process for setting up and using the Orion Star A214?

A: Set up involves connecting the appropriate electrodes (BNC, reference, and temperature), selecting the measurement mode via the touch keypad, and calibrating as needed. The user-friendly LCD display guides the process, while the adjustable electrode stand facilitates sample immersion during readings.

Q: How does GLP compliance benefit laboratory operations with this meter?

A: GLP compliance ensures the meter provides traceable documentation and calibration logs, supporting laboratory quality assurance requirements. This feature is essential for organizations that must meet strict regulatory and validation standards during analytical processes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical LAB' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.