Product Description
| Brand |
Snibe |
| Sample Type |
Serum |
| Pack Size |
100T |
| CAT No. |
130203010M |
| Application |
Thyroid Marker |
The kit has been designed for the quantitative determination of Reverse Triiodothyronine (Rev T3) in human serum. The method can be used for samples over the range of 0.05-10.0ng/ml. The test has to be performed on the Fully-auto chemiluminescence immunoassay (CLIA) analyzer MAGLUMI (Including Maglumi 600,Maglumi 1000,Maglumi 1000 Plus, Maglumi 2000,Maglumi 2000 Plus,Maglumi 3000 and Maglumi 4000).
Advanced CLIA Technology for Rev T3 MeasurementPowered by indirect chemiluminescence, the Snibe MAGLUMI Rev T3 kit leverages a two-step sandwich immunoassay format to precisely quantify Reverse Triiodothyronine levels. This technology ensures high analytical sensitivity and specificity in each test, crucial for clinical diagnostics and patient monitoring.
Seamless Integration and Automated ProcessingThe reagent kit is fully compatible with MAGLUMI Series Immunoassay Analyzers and comes with all necessary components, including labeled colorless vials and ready-to-use reagents. Automation minimizes manual steps, reducing hands-on time and the risk of error, while consistent accuracy is ensured by adherence to reference standards.
Reliable and Safe for Clinical UseDesigned for professional use in hospitals, diagnostic centers, and labs, this kit complies with biosafety precautions. With a measurement range of 0.04-8.0 ng/mL and accurate controls, it is ideal for routine and specialized thyroid testing. Store at 2-8C for optimal kit longevity.
FAQ's of Snibe MAGLUMI Rev T3 (CLIA):
Q: How does the Snibe MAGLUMI Rev T3 kit measure Reverse Triiodothyronine in samples?
A: The kit utilizes an indirect chemiluminescence (CLIA) two-step sandwich immunoassay to detect and quantify Reverse Triiodothyronine (Rev T3) in human serum or plasma. The process is automated and requires a MAGLUMI Immunoassay Analyzer for operation.
Q: What components are included in the Snibe MAGLUMI Rev T3 kit?
A: Each kit contains ready-to-use reagents, calibrators, controls, and detailed instructions for use. These components are provided in colorless, labeled plastic vials specifically intended for in-vitro diagnostic use.
Q: Where can the Snibe MAGLUMI Rev T3 kit be used and who is it intended for?
A: This reagent kit is designed for professional use in hospitals, clinical laboratories, and diagnostic centers. Its use is limited to trained laboratory personnel following proper biosafety procedures.
Q: What is the process and sample requirement for performing the test?
A: To conduct the test, simply add 80 L of serum or plasma sample to the MAGLUMI Analyzer using the supplied reagents. The analyzer then fully automates the measurement process, delivering quantitative results within the indicated range.
Q: When should the kit be stored and how long does it last?
A: The kit should be stored at 2-8C immediately upon receipt and kept refrigerated when not in use. Do not freeze. Under proper conditions, the kit remains stable for 12 months from the date of manufacture.
Q: What are the benefits of using this kit over conventional methods?
A: The Snibe MAGLUMI Rev T3 kit offers high sensitivity and specificity, automated processing, consistent accuracy matching reference standards, and reduced manual handling, yielding more efficient and reliable diagnostic results for thyroid function assessment.