Product Description
| Brand |
Snibe |
| Sample Type |
Serum |
| Pack Size |
100T |
| CAT No. |
130259005M |
| Application |
Liver Marker |
The kit has been designed for the quantitative determination of Cholylglycine (CG) in human serum. The method can be used for samples over the range of 0.06-40.0g/ml. The test has to be performed on the Fully-auto chemiluminescence immunoassay (CLIA) analyzer MAGLUMI (Including Maglumi 600,Maglumi 1000,Maglumi 1000 Plus, Maglumi 2000,Maglumi 2000 Plus,Maglumi 3000 and Maglumi 4000).
Advanced Sandwich Immunoassay TechnologyThe Snibe MAGLUMI Cholylglycine kit employs a chemiluminescent sandwich immunoassay, harnessing specific antibodies for accurate detection. This method enhances analytical sensitivity and supports quantitative analysis of CG in human samples.
Streamlined Workflow for LaboratoriesWith complete, ready-to-use packaging and full automation compatibility, the kit allows laboratory professionals to perform CG measurements efficiently. The typical assay time is approximately 30 minutes, optimizing throughput without compromising accuracy.
Reliable Performance and Ease of UseValidated for lot-to-lot consistency, the Snibe MAGLUMI kit guarantees reproducibility and precision. Professionals benefit from intuitive procedures, clear labeling, and robust quality performance consistent with manufacturer standards.
FAQ's of Snibe MAGLUMI Cholylglycine (CLIA):
Q: How is the Snibe MAGLUMI Cholylglycine (CLIA) kit used in the laboratory?
A: The kit is intended for professional laboratory personnel and is used with the MAGLUMI automated analyzers. It quantifies cholylglycine in human serum or plasma through a sandwich immunoassay technique, offering results in around 30 minutes.
Q: What is the measurement range and sensitivity of the test?
A: The MAGLUMI Cholylglycine kit accurately measures CG concentrations ranging from 2.5 to 150 mol/L, delivering high sensitivity and specificity as per the manufacturer's validated quality standards.
Q: When should reagents from the kit be stored or discarded?
A: Kit reagents should be stored at a temperature between 2-8C and must not be frozen. They have a shelf life of 12 months, provided proper storage conditions are maintained. Discard any reagents past their expiration date or if storage conditions are compromised.
Q: Where can the Snibe MAGLUMI Cholylglycine (CLIA) kit be used?
A: This reagent kit is intended strictly for use in professional diagnostic laboratories equipped with MAGLUMI chemiluminescence immunoassay analyzers. It is not suitable for point-of-care or home use.
Q: What is the main process for analyzing cholylglycine using this kit?
A: The process involves loading serum or plasma samples and the supplied reagents into the MAGLUMI analyzer. The instrument automates the sandwich immunoassay, detects CG via chemiluminescence, and reports quantitative results within approximately 30 minutes.
Q: What are the benefits of using this CLIA kit for cholylglycine detection?
A: Users benefit from high throughput, consistent accuracy, automation compatibility, and reduced hands-on time. The kit's validated lot-to-lot reliability ensures precise and reproducible results for clinical diagnostics.
Q: Is the kit compatible with other analyzers besides MAGLUMI?
A: No, this kit is exclusively designed for use with MAGLUMI chemiluminescence immunoassay analyzers and cannot be used on other platforms or brands.