Product Description
| Brand | Abbott |
| Stent Diameter (mm) | 3.50 |
| Stent Length (mm) | 16, 19, 26, 29 |
| CAT No | 1012818-16, 1012818-19, 1012818-26, 1012818-29 |
| Catheter Length | 143 cm |
The GRAFTMASTER RX Coronary Stent Graft System is indicated for use in the treatment of free perforations, defined as free contrast extravasation into the pericardium, in native coronary vessels or saphenous vein bypass grafts 2.75 mm in diameter. The effectiveness of this device for this use has not been demonstrated. Long-term outcome for this permanent implant is unknown at present.
Precision Engineering for Challenging CasesThe Abbott GRAFTMASTER RX SD 3.5 is precision-crafted for managing complex coronary artery scenarios, including vessel perforations. Its balloon-expandable, cobalt chromium stent provides robust support, while the PTFE graft ensures rapid sealing. The system enables swift and accurate navigation using a rapid exchange delivery design, minimizing procedural time and enhancing safety during intervention.
Exceptional Compatibility and FlexibilityDesigned for compatibility with a 0.014 inch (0.36 mm) guidewire, this stent graft system offers flexibility during coronary interventions. The catheter's usable length of 138 cm and nominal pressure rating of 8 atm (RBP 16 atm) provide the confidence required for interventional cardiologists to address a range of coronary vessel sizes and conditions.
FAQ's of Abbott GRAFTMASTER RX Coronary Stent Graft System (SD 3.5):
Q: How does the Abbott GRAFTMASTER RX SD 3.5 function during coronary artery repair?
A: The Abbott GRAFTMASTER RX SD 3.5 is inserted using a rapid exchange balloon catheter, which positions the balloon-expandable stent covered with PTFE graft material at the target site. Upon inflation, the stent expands to seal vessel perforations and support the vessel wall, restoring vessel integrity.
Q: What is the process for deploying the GRAFTMASTER RX SD 3.5 in a coronary procedure?
A: The device is advanced over a 0.014 inch (0.36 mm) guidewire to the target location in the coronary artery. The balloon is then inflated to the required pressure (up to 16 atm rated burst) to expand the stent and graft, after which the delivery system is removed, leaving the stent in place.
Q: When should the GRAFTMASTER RX SD 3.5 be used?
A: This stent graft system is typically used when there is a need to seal a coronary artery perforation or to reinforce the vessel wall during interventional cardiac procedures, especially in instances of vessel trauma or complication.
Q: What are the key benefits of using the GRAFTMASTER RX SD 3.5 stent graft system?
A: Benefits include rapid and effective sealing of vessel perforations, precise placement due to the rapid exchange system, high compatibility with standard guidewires, and a reliable, sterile, latex-free structure suitable for coronary procedures.
Q: Where should the Abbott GRAFTMASTER RX SD 3.5 be stored prior to use?
A: The stent graft should be stored at room temperature, protected from moisture and direct sunlight, to maintain its sterility and efficacy until the expiration date or shelf life limit.
Q: Is the GRAFTMASTER RX SD 3.5 compatible with real-time operation and portable use?
A: Yes, the device is designed for real-time manual operation during interventions, and its lightweight, portable design allows easy transport and handling in various clinical settings.
Q: How do users ensure correct sizing with the GRAFTMASTER RX SD 3.5?
A: Correct vessel measurement and preparation is essential. The stent measures 3.5 mm in diameter and 16 mm in length, making it suitable for sealing perforations or supporting vessel repair in appropriately sized coronary arteries.