Product Description
Brand BioRad
Model EVOLIS
Capacity 192 Wells
CAT No 93500B
Application Immunology
Fully automated and truly open system; includes EVOLIS Twin Plus Analyzer and accessory box (1 system)
Advanced Automation for Clinical DiagnosticsThe EVOLIS Twin Plus System delivers walk-away automation for ELISA processing in laboratories. Its open system architecture and random access capabilities allow laboratories to handle varied assay types efficiently. Intuitive software and integrated barcode scanning simplify sample tracking. With onboard memory to store protocols and results, labs benefit from streamlined workflows and reduced manual errors, supporting efficient, high-quality diagnostics in busy clinical settings.
High Throughput and Precision in Every RunDesigned to maximize laboratory productivity, the EVOLIS Twin Plus processes up to 189 samples and 7 plates per run while maintaining pipetting precision below 3% CV. The integrated multi-channel washer and incubator ensure reliable assay performance, while halogen lamp illumination guarantees precise photometric readings. The system's capacity and accuracy make it ideal for laboratories requiring consistent, high-volume ELISA testing.
Seamless Connectivity and Data ManagementWith built-in RS232 serial and USB ports, the EVOLIS Twin Plus easily synchronizes with Laboratory Information Systems (LIS) and PCs. The robust Bio-Rad software supports protocol creation and result archival, helping laboratories meet compliance and traceability needs. Barcode integration further enhances workflow, minimizing identification errors and supporting comprehensive sample tracking throughout the testing process.
FAQ's of BioRad EVOLIS Twin Plus System:
Q: How does the EVOLIS Twin Plus System improve ELISA workflow efficiency?
A: The system automates every step of ELISA processing, from sample loading to result capture, enabling up to 7 plates and 189 samples per run. This reduces manual intervention, minimizes errors, and supports consistent high-throughput performance.
Q: What level of precision can I expect from the pipetting process?
A: The EVOLIS Twin Plus ensures high pipetting precision with a coefficient of variation (CV) of less than 3%. This accuracy is maintained across its automated operations, promoting reliable and reproducible results for clinical diagnostics.
Q: When is this system most beneficial in a clinical laboratory setting?
A: This system is ideal for laboratories requiring routine, high-volume ELISA testing with minimal hands-on time. Its walk-away automation and open system design allow for flexible operation and simplified management of diverse assays.
Q: Where can the EVOLIS Twin Plus System be installed?
A: It is intended for placement on laboratory benches due to its dimensions (approximately 121 x 66 x 53 cm) and weight (about 88 kg). The system is not wall-mounted or portable and operates in environments with temperatures from 15C to 32C and humidity between 15% and 85% (non-condensing).
Q: What is the process for data integration with laboratory systems?
A: The instrument offers multiple data transmission modes via RS232 serial and USB ports. It synchronizes seamlessly with Laboratory Information Systems (LIS) and PCs, allowing real-time protocol management and result recording through the Bio-Rad EVOLIS software.
Q: How can the EVOLIS Twin Plus benefit clinical laboratories in India?
A: Its automated operation, LIS compatibility, high throughput, and support for disposable reagents make it well suited for the diverse requirements of clinical diagnostics in India, reducing turnaround times and improving overall laboratory productivity.