Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS
Mindray Ferritin (CLIA) Mindray Ferritin (CLIA) Mindray Ferritin (CLIA)
Mindray Ferritin (CLIA)
Mindray Ferritin (CLIA) Mindray Ferritin (CLIA)

Mindray Ferritin (CLIA)

Product Details:

  • Features High sensitivity, high precision, suitable for Mindray CLIA analyzers
  • Usage Type Clinical laboratory diagnostic use
  • Instruments Type Clinical Chemistry/Immunoassay
  • Accuracy Conforms to clinical standards (according to manufacturer)
  • Shelf Life 12 months
  • Measurement Range Varies depending on analyzer model, compatible with Mindray analyzers
  • Function Ferritin measurement
  • Click to View more
X

Mindray Ferritin (CLIA) Price And Quantity

  • 1 Unit

Mindray Ferritin (CLIA) Product Specifications

  • For quantitative determination of ferritin in human serum/plasma
  • Varies depending on analyzer model, compatible with Mindray analyzers
  • Clinical Chemistry/Immunoassay
  • N/A (Kit packaging standard size)
  • Clinical laboratory diagnostic use
  • Ferritin measurement
  • Not specified (kit packaging varies)
  • Yes
  • 12 months
  • Ferritin Assay Kit (CLIA)
  • High sensitivity, high precision, suitable for Mindray CLIA analyzers
  • Store at 2-8 Degree Celsius , protect from light
  • Other
  • Automatic
  • Conforms to clinical standards (according to manufacturer)
  • Yes (as kit)
  • New
  • Other
  • No
  • Chemiluminescence Immunoassay (CLIA)
  • Two-site sandwich CLIA
  • Quantitative, analyzer provides concentration in ng/mL
  • Minimum sample volume required as per protocol
  • Detection of iron deficiency, anemia, inflammation, and chronic disease diagnosis
  • Depends on instrument, typically 10-20 minutes
  • Mindray CL-900i, CL-1000i, CL-1200i, CL-2000i, and similar CLIA analyzers
  • Medical professionals, laboratory personnel
  • As per analyzer specification (refer to manual)
  • Calibrators, controls, reagents, disposable materials

Product Description


Brand Mindray
Sample Type Serum
Pack Size 2 x 50T, 2 x 100T
CAT No. 10500422000, 10500424700
Mindray Ferritin is a chemiluminescent immunoassay reagent designed for the quantitative measurement of ferritin in human serum. The assay is intended for use with compatible Mindray automated chemiluminescence immunoassay analyzers. Ferritin is the major intracellular iron-storage protein and its circulating concentration generally reflects body iron stores, although ferritin can also increase in inflammatory and other clinical conditions.

Advanced Ferritin Detection for Clinical Laboratories

Experience robust and accurate ferritin measurement using the Mindray Ferritin (CLIA) Assay Kit. The kit delivers high precision and sensitivity, ensuring reliable detection of iron-related disorders and chronic inflammation. Its compatibility with various Mindray CLIA analyzers streamlines laboratory workflow and supports effective screening in both routine and specialized diagnostic settings.


Efficient and Automated Operation

Mindray's Ferritin Assay Kit is engineered for automatic use on CLIA analyzers, minimizing manual intervention. With sample results typically available within 10-20 minutes and quantitative reporting, this kit enhances productivity and accuracy in clinical laboratory operations, making it a preferred choice for medical professionals and laboratory personnel.


User-Focused Design and Complete Package

The kit includes all essential components-reagents, calibrators, controls, and disposables-ensuring a smooth and comprehensive testing experience. Its standard packaging and clear storage instructions support convenient handling and optimal reagent stability, while the kit's moderate portability suits the needs of busy diagnostic centers.

FAQ's of Mindray Ferritin (CLIA):


Q: How is the Mindray Ferritin (CLIA) Assay Kit used in clinical laboratories?

A: The assay kit is used for the quantitative measurement of ferritin in human serum or plasma. Medical professionals and laboratory personnel load samples into a compatible Mindray CLIA analyzer, which then performs the two-site sandwich assay automatically.

Q: What instruments are compatible with the Mindray Ferritin (CLIA) Assay Kit?

A: This kit is designed for use with Mindray CL-900i, CL-1000i, CL-1200i, CL-2000i, and other similar CLIA analyzers, ensuring broad applicability in various laboratory setups.

Q: When are ferritin measurements indicated using this kit?

A: Ferritin testing is indicated when evaluating patients for iron deficiency, anemia, inflammation, or chronic diseases, as ferritin levels provide crucial insights into iron stores and inflammatory activity.

Q: Where should the Mindray Ferritin (CLIA) Kit be stored for optimal performance?

A: For best results, store the assay kit at 2-8C and protect it from light. These conditions help maintain reagent integrity throughout its 12-month shelf life.

Q: What is the process for performing the ferritin assay with this kit?

A: After the patient sample is loaded per protocol, the analyzer automatically mixes it with specific reagents. The two-site sandwich CLIA technology quantifies ferritin, and results are typically delivered in 10-20 minutes as a concentration in ng/mL.

Q: How do users benefit from using the Mindray Ferritin (CLIA) Kit?

A: Users benefit from its high sensitivity, precise results, rapid turnaround, and reduced manual handling, which support accurate and efficient diagnosis of iron and inflammatory disorders in clinical settings.

Q: What precautions should be followed during storage and handling of the kit?

A: Always store the kit at 2-8C, avoid exposure to direct light, and handle all reagents as instructed in the manual to ensure test accuracy and kit longevity.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical CLIA' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.