Product Details:

  • Feature High purity standards, tightly defined MW distribution, APC optimized
  • Measurement Range Nominally up to 370,000 g/mol (middle MW range)
  • Temperature Range Ambient (storage); usage typically 15-40C
  • Core Components Six calibration standards of defined molecular weights
  • Accuracy Certified MW values traceable to international standards
  • Model No APC Polymethylmethacrylate Middle MW Calibration Kit
  • Capacity Set of 6 ampoules, each 3 mL
  • Click to View more
X

Waters Corp ACQUITY APC Polymethylmethacrylate Middle MW Calibration Kit Price And Quantity

Waters Corp ACQUITY APC Polymethylmethacrylate Middle MW Calibration Kit Product Specifications

  • Ambient (storage); usage typically 15-40C
  • Nominally up to 370,000 g/mol (middle MW range)
  • High purity standards, tightly defined MW distribution, APC optimized
  • Not specified / negligible per ampoule
  • Each ampoule: standard vial size; kit: box packaging
  • Six calibration standards of defined molecular weights
  • APC Polymethylmethacrylate Middle MW Calibration Kit
  • Polymethylmethacrylate in THF (Tetrahydrofuran) solvent
  • Set of 6 ampoules, each 3 mL
  • Certified MW values traceable to international standards
  • Calibration of Advanced Polymer Chromatography (APC) / GPC SEC instruments
  • Polymethylmethacrylate Middle Molecular Weight (MW) Calibration Kit
  • Pre-measured liquid ampoules
  • Store at room temperature, away from light
  • Refer to package label (typically 2 years from manufacture)
  • THF (Tetrahydrofuran)
  • For laboratory use only; not for medical, diagnostic, or food use
  • SEC/GPC/APC system calibration and performance verification
  • Approximately 11,000 370,000 g/mol

Product Description

Brand                         Waters Corp

Sample Type             Calibration Kit

Pack Size                  30 Nos

CAT No                     186007544

Application               Protein

APC Calibration Standards were specifically designed to match the molecular weight range of the ACQUITY APC XT Columns.  They eliminate the need to manually prepare custom standard calibration mixes as ACQUITY APC Calibration Standards provide the right number of data points for the targeted MW range. The calibration standards come in 12 x 32 mm amber glass vials with PTFE/silicone septa.  The cap color indicates the MW standards in the vial.  Simply add solvent to the vial, to dissolve the standards and place vial in the autosampler following the instructions provided.




Certified Performance for Accurate Calibration

This calibration kit features certified molecular weight values traceable to international standards, ensuring precise calibration of APC, GPC, and SEC systems. By using high-purity polymethylmethacrylate in THF, laboratories can achieve dependable performance verification and consistency in results across multiple runs.


Convenient Pre-Measured Ampoules

Each kit contains six pre-measured 3 mL ampoules, simplifying setup and minimizing potential handling errors. This convenient format supports efficient workflow and reproducibility, as each ampoule delivers the exact amount required for calibration.


Designed for Laboratory Use Only

Intended strictly for laboratory applications, this kit is not suitable for medical, diagnostic, or food purposes. Store the ampoules at ambient temperature away from light for optimal shelf life and integrity of the calibration standards.

FAQ's of Waters Corp ACQUITY APC Polymethylmethacrylate Middle MW Calibration Kit:


Q: How do I use the ACQUITY APC Polymethylmethacrylate Middle MW Calibration Kit for system calibration?

A: To use the kit, select an ampoule, gently mix, and inject the contents into your SEC/GPC/APC instrument according to your standard calibration protocol. The kit is designed for straightforward instrument calibration and performance verification.

Q: What are the benefits of using pre-measured liquid ampoules in this calibration kit?

A: Pre-measured ampoules reduce preparation time and minimize handling errors, ensuring consistent results and accurate calibration. This enhances workflow efficiency and repeatability across routine calibrations.

Q: When should I replace the calibration standards in my laboratory?

A: You should use the calibration standards within the shelf life specified on the package label-typically two years from the date of manufacture. Replace the kit if any ampoule shows signs of degradation or after reaching its expiration date.

Q: Where should I store the ampoules to preserve their quality?

A: Store the ampoules at room temperature, away from light, as recommended. These conditions help to maintain the integrity and purity of the polymethylmethacrylate solutions throughout the product's shelf life.

Q: What is the molecular weight range covered by the calibration kit?

A: The kit includes six standards spanning a molecular weight range of approximately 11,000 to 370,000 g/mol, suitable for middle-range polymer calibration applications.

Q: How does this kit ensure traceable and reliable calibration results?

A: Certified molecular weight values are provided for each standard, traceable to international standards. This certification guarantees accurate and reproducible results when calibrating advanced polymer chromatography instruments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Life Sciences' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.