Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS    Call Me Free
Terumo RUNTHROUGH NS HYPERCOAT Coronary Guidewire Terumo RUNTHROUGH NS HYPERCOAT Coronary Guidewire Terumo RUNTHROUGH NS HYPERCOAT Coronary Guidewire
Terumo RUNTHROUGH NS HYPERCOAT Coronary Guidewire
Terumo RUNTHROUGH NS HYPERCOAT Coronary Guidewire Terumo RUNTHROUGH NS HYPERCOAT Coronary Guidewire

Terumo RUNTHROUGH NS HYPERCOAT Coronary Guidewire

Product Details:

  • Shelf Life Up to 3 years (unopened)
  • Measurement Range Typical for 0.014 guidewires
  • Accuracy High precision navigation
  • Instruments Type Interventional cardiology accessory
  • Usage Type Single-use, disposable
  • Storage Instructions Store in a cool, dry place; avoid direct sunlight
  • Features Excellent torque control, smooth navigation, kink resistance, hydrophilic coating
  • Click to View more
X

Terumo RUNTHROUGH NS HYPERCOAT Coronary Guidewire Price And Quantity

Terumo RUNTHROUGH NS HYPERCOAT Coronary Guidewire Product Specifications

  • Typical for 0.014 guidewires
  • Manual
  • Blue and gold
  • Interventional cardiology accessory
  • Yes
  • Single-use, disposable
  • Excellent torque control, smooth navigation, kink resistance, hydrophilic coating
  • Store in a cool, dry place; avoid direct sunlight
  • Facilitates coronary vessel access and lesion crossing
  • New
  • Silent operation
  • High precision navigation
  • Length: 180 cm
  • Lightweight (Approx. 1 2 g per unit)
  • No
  • Coronary interventions, PCI procedures
  • NS Hypercoat hydrophilic coating technology
  • Up to 3 years (unopened)
  • Coronary Guidewire
  • Yes
  • Nitinol core with stainless steel distal coil

Product Description

Brand Terumo
Tip Radiopacity 3 cm
Tip Shape Straight
CAT No TW-DS430FH
Wire Length 300 cm

Designed to be your complex coronary wire of choice. Runthrough NS Hypercoat is an enhanced hydrophilic guidewire for tortuous, distal lesions and tight stenotic complex lesions.



Advanced Hydrophilic Coating for Smooth Navigation

The RUNTHROUGH NS HYPERCOAT features an NS Hypercoat hydrophilic coating along the 24 cm distal segment. This reduces friction significantly, enabling the guidewire to traverse complex or tortuous coronary vessels with ease, contributing to greater procedural efficiency and reduced risk of vessel trauma.


Superior Torque Transmission and Kink Resistance

Engineered with a nitinol core and stainless steel distal coil, this guidewire offers exceptional torque control and resistance to kinking. Clinicians can confidently navigate challenging anatomies, as the device translates rotational input precisely to the tip, enhancing procedural accuracy and safety.


High-Visibility Design for Reliable Placement

Its radiopaque distal segment guarantees clear visibility under fluoroscopic imaging, allowing for accurate positioning and tracking throughout the intervention. The combination of visibility and precision-oriented construction ensures optimal outcomes in coronary vessel access and lesion crossing.

FAQs of Terumo RUNTHROUGH NS HYPERCOAT Coronary Guidewire:


Q: How does the hydrophilic NS Hypercoat benefit coronary interventions?

A: The NS Hypercoat hydrophilic coating on the distal 24 cm segment reduces surface friction, allowing the guidewire to move smoothly through vessels. This minimizes the risk of vessel trauma, facilitates easier navigation, and enhances overall procedural efficiency during coronary interventions.

Q: What types of tip shapes are available with the RUNTHROUGH NS HYPERCOAT Guidewire?

A: This guidewire is available with both Straight and J-tip configurations. Each tip features flexible tapering, which assists with smooth, atraumatic vessel entry and crossing of lesions in a variety of clinical scenarios.

Q: When should the RUNTHROUGH NS HYPERCOAT Guidewire be used?

A: The guidewire is intended for use during adult coronary interventions, particularly percutaneous coronary interventions (PCI). It is suitable for procedures requiring precise vessel access and lesion crossing.

Q: Where can I use this coronary guidewire, and is it compatible with standard equipment?

A: The RUNTHROUGH NS HYPERCOAT is compatible with standard diagnostic catheters, making it applicable in any cath lab or interventional cardiology setting. Its standard 0.014 diameter makes it suitable for a wide range of coronary procedures.

Q: What is the proper process for storing and using this guidewire?

A: Store the guidewire in a cool, dry place, away from direct sunlight, and maintain its packaging sealed until use. Always use the guidewire as a single-use, disposable devicediscarding after one procedure ensures patient safety.

Q: What are the key benefits of using this guidewire during procedures?

A: Key benefits include excellent torque response, smooth vessel navigation, high precision, resistance to kinking, and clear visibility under imaging. These features help to improve procedural success rates and minimize complications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical Surgicals' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.