Product Description
| Brand | Metrohm |
| Material | PEEK |
| Capacity | 5 x 4.0 mm |
| CAT No | 61051500 |
| Application | Titration Accessories |
The Metrosep C 6 Guard/4.0 contains the C 6 column material and is used to protect against particles and contamination. This considerably lengthens the service life of the analytical separation column. The Metrosep C 6 Guard/4.0 works according to the "On Column Guard System" and is screwed directly onto the respective separation column with virtually no dead volume.
Optimal Column ProtectionSafeguard your analytical investments with the Metrosep C 6 Guard/4.0. Specially engineered for Metrohm Metrosep C 6 series columns, it intercepts particulates and chemical contaminants, thereby reducing the frequency of column replacements. This guard column ensures a consistent and reliable chromatographic workflow, making it indispensable for labs demanding high accuracy and longevity from their ion chromatography equipment.
Easy Installation and CompatibilityDesigned with user convenience in mind, the Metrosep C 6 Guard/4.0 features a standard Metrohm guard end fitting and lightweight housing, allowing effortless inline integration. Its plug & play design means no complex procedures or additional power requirements. The guard column's robust construction and compatibility with Metrohm systems streamline its incorporation into existing setups, reducing downtime and increasing productivity.
FAQ's of Metrohm Metrosep C 6 Guard/4.0:
Q: How is the Metrosep C 6 Guard/4.0 installed into a Metrohm ion chromatography system?
A: Installation is straightforward thanks to its standard Metrohm guard end fitting. Simply connect the unit inline with your Metrosep C 6 analytical column using plug & play methods, requiring no special tools or technical expertise.
Q: What is the benefit of using this guard column with the Metrosep C 6 series?
A: The guard column extends the life of your analytical column by suppressing and eliminating sample contaminants before they reach the primary column, thus maintaining consistent separation performance and reducing maintenance costs.
Q: When should the Metrosep C 6 Guard/4.0 be replaced?
A: Typically, the guard column is effective for up to 300 injections. However, replacement may be necessary sooner if frequent sample contamination or a noticeable loss in chromatographic efficiency occurs.
Q: Where can I purchase the Metrosep C 6 Guard/4.0 in India?
A: This product is available through authorized Metrohm dealers, distributors, exporters, manufacturers, suppliers, traders, and wholesalers across India. Contact your preferred vendor for availability and support.
Q: What process does the guard column use to protect the analytical column?
A: It utilizes quaternary ammonium functionalized resin to adsorb and retain ionic contaminants and particulates, preventing these from entering and potentially damaging the analytical column during ion chromatography.
Q: What is the usage protocol for maximum shelf life of the guard column?
A: To maximize shelf life, store the guard column unopened in a cool, dry environment. Its shelf life is two years if properly stored and unopened before use.
Q: Is the Metrosep C 6 Guard/4.0 compatible with systems other than the Metrosep C 6 series?
A: This guard column is specifically designed for the Metrohm Metrosep C 6 series columns. For use with other systems, consult Metrohm's compatibility guidelines or contact technical support for recommendations.