Product Details:

  • Storage Instructions Store at 230C, Do Not Freeze
  • Instruments Type Diagnostic Test Kit
  • Frequency As Required/Tested
  • Function Detection of Cotinine (Nicotine Metabolite)
  • Measurement Range Cut-off: 200 ng/mL Cotinine
  • Accuracy >99% (According to Manufacturer)
  • Display Type Visual Line Readout
  • Click to View more
X

Acro Biotech JusChek COT10 Rapid Test Cassette (Whole Blood/ Serum/ Plasma) Price And Quantity

Acro Biotech JusChek COT10 Rapid Test Cassette (Whole Blood/ Serum/ Plasma) Product Specifications

  • White Cassette
  • Store at 230C, Do Not Freeze
  • Visual Line Readout
  • Rapid Test Cassette
  • Plastic Cassette, Test Strip
  • >99% (According to Manufacturer)
  • Qualitative Detection of Cotinine (COT) in Whole Blood, Serum, or Plasma
  • Yes
  • 18-24 Months (Unopened)
  • Detection of Cotinine (Nicotine Metabolite)
  • As Required/Tested
  • Individually Sealed Cassette, Approx. 7 x 2.5 x 0.5 cm
  • Single Use Only
  • Diagnostic Test Kit
  • Approx. 10 g per cassette
  • Immunochromatographic Assay
  • Easy to Use, Rapid Results in 5 Minutes, No Equipment Needed, Clear Interpretation Window
  • New
  • Silent/None
  • No
  • Yes
  • Cut-off: 200 ng/mL Cotinine
  • Manual
  • Built-in for Test Validity
  • Clear Window for Immediate Results
  • Each Cassette Individually Foil Wrapped with Dropper and Desiccant
  • Whole Blood, Serum, Plasma
  • 5 Minutes

Acro Biotech JusChek COT10 Rapid Test Cassette (Whole Blood/ Serum/ Plasma) Trade Information

  • 100 Unit Per Day
  • 1-7 Days

Product Description

Brand Acro Biotech
Sample Type Serum/ Plasma/ WB
Pack Size 25T
CAT No DCT-402

The COT Rapid Test is a rapid screening test that can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect elevated levels of Cotinine in specimen.




Quick and User-Friendly Cotinine Detection

The Acro Biotech JusChek COT10 Rapid Test Cassette allows for straightforward, on-the-spot detection of cotinine in whole blood, serum, or plasma. Its plastic cassette format ensures ease of handling without the need for extra devices. Results appear within just 5 minutes thanks to immunochromatographic assay technology, helping healthcare professionals and organizations make timely, informed decisions.


Portable and Convenient Design

Weighing just 10 grams and measuring only 7 x 2.5 x 0.5 cm, each test is individually sealed and ready for single use. The cassette requires no power or equipment, making it suitable for clinics, outreach programs, and on-the-go testing needs. Shelf-stable for up to two years, it only needs to be stored between 2-30C; never freeze the kits.


Reliable Visual Readout and Quality Assurance

A built-in control line ensures the validity of each result, while the clear, easy-to-read window facilitates immediate interpretation. With manufacturer-stated accuracy greater than 99% and a qualitative cut-off of 200 ng/mL for cotinine, users can trust in the reliability of every tested sample.

FAQ's of Acro Biotech JusChek COT10 Rapid Test Cassette (Whole Blood/ Serum/ Plasma):


Q: How is the Acro Biotech JusChek COT10 Rapid Test Cassette used?

A: To use the test, add a sample of whole blood, serum, or plasma to the sample well with the provided dropper, then wait 5 minutes for the results to appear in the clear read window. No additional equipment is necessary.

Q: What substances does this rapid test detect?

A: The cassette is specifically designed to detect cotinine, a metabolite of nicotine, at concentrations of 200 ng/mL or greater in whole blood, serum, or plasma samples.

Q: When should I read the test results?

A: Results should be read exactly at 5 minutes after sample addition. Interpretation should not be made after 10 minutes as results may be invalid beyond this period.

Q: Where can the test be performed?

A: The rapid test can be conducted in clinics, laboratories, or field settings since it is portable, requires no equipment, and produces silent operation.

Q: What is the process for interpreting results in the read window?

A: A clear visual indication appears in the read window. The presence of two lines (control and test) indicates a negative result, while one control line only signifies a positive result. The control line confirms the test's validity.

Q: Is this test cassette intended for single or multiple uses?

A: Each cassette is designed for single use only. After use, it should be properly disposed of according to local guidelines.

Q: What benefits does this test offer to healthcare providers and users?

A: Benefits include its rapid turnaround time, high accuracy (>99%), ease of use, portability, and no requirement for specialized lab equipment, making it ideal for quick decision-making and large-scale screening.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical RTD' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.