Product Details:

  • Usage Type Single Use
  • Accuracy High steerability and precision
  • Shelf Life 3 Years
  • Measurement Range 0.018 (Diameter), 180 cm (Length)
  • Features Excellent torque response, shapeable tip, fluoroscopic visibility, kink resistance, lubricious coating
  • Instruments Type Guide Wire
  • Function Navigation and support during endovascular procedures
  • Click to View more
X

Abbott Hi-Torque Command 18 LT Guide Wires Price And Quantity

Abbott Hi-Torque Command 18 LT Guide Wires Product Specifications

  • Metallic with polymer jacket
  • No
  • 3 Years
  • Store in a dry, cool place away from sunlight
  • Length: 180 cm, Diameter: 0.018 (0.46 mm)
  • Navigation and support during endovascular procedures
  • High steerability and precision
  • Guide Wire
  • New
  • Yes
  • Excellent torque response, shapeable tip, fluoroscopic visibility, kink resistance, lubricious coating
  • 0.018 (Diameter), 180 cm (Length)
  • Lightweight
  • Peripheral Guide Wire
  • Manual
  • Yes
  • Single Use
  • Stainless Steel Core
  • Hi-Torque Technology
  • Peripheral Vascular Interventions

Product Description

Brand Abbott
Wire Diameter 0.018 in
Tip Shape Straight
CAT No 1013753
Wire Length 300 cm

Hi-Torque Guide Wire is intended to facilitate the placement of balloon dilatation catheters during percutaneous transluminal angioplasty (PTA), in arteries such as the femoral, popliteal and infra-popliteal arteries. This guide wire may also be used with compatible stent devices during therapeutic procedures.



Superior Performance in Peripheral Vascular Interventions

Engineered for high steerability and torque response, the Abbott Hi-Torque Command 18 LT ensures clinicians can reliably navigate complex vascular anatomy. The shapeable and flexible tip, combined with kink-resistant construction, allows safe passage through challenging lesions with remarkable accuracy.


Innovative Hydrophilic Coating for Smooth Navigation

A hydrophilic polymer-coated distal segment dramatically reduces friction, enhancing the wires lubricity as it interacts with vessel walls and lesions. This design greatly improves ease of use and minimizes potential trauma during complex endovascular procedures.


Precision and Visibility Under Fluoroscopy

Featuring a radiopaque tip, the guide wire delivers outstanding fluoroscopic visibility. Clinicians can confidently position and manipulate the wire under real-time imaging, ensuring precise advancement and access throughout the procedure.

FAQs of Abbott Hi-Torque Command 18 LT Guide Wires:


Q: How is the Abbott Hi-Torque Command 18 LT guide wire used during peripheral vascular procedures?

A: This guide wire is utilized to navigate through blood vessels, cross lesions, or provide access for other interventional devices during peripheral vascular procedures, offering precise maneuverability and support.

Q: What are the key benefits of the hydrophilic polymer-coated distal segment?

A: The hydrophilic coating significantly reduces friction, enabling smooth vessel access and passage through lesions while minimizing vessel trauma and improving procedural efficiency.

Q: When is this guide wire suitable for use?

A: It is suitable for single-use peripheral vascular interventions, particularly in situations that require high steerability, torque control, and visibility during navigation and lesion crossing.

Q: Where should the Abbott Hi-Torque Command 18 LT guide wire be stored when not in use?

A: Store the sealed, sterile guide wire in a dry, cool place away from direct sunlight to maintain its integrity and extend its shelf life.

Q: What makes the product compatible with peripheral interventions involving 0.018" device systems?

A: With its 0.018-inch (0.46 mm) diameter and 180 cm length, the guide wire integrates seamlessly with compatible device systems, facilitating versatile use across various peripheral interventions.

Q: What process ensures the sterility of each guide wire?

A: Each individual product is EO gas sterilized and packaged in a peel-open pouch, maintaining strict sterility standards required for medical devices.

Q: What is the main advantage of the radiopaque tip during procedures?

A: The radiopaque tip enhances fluoroscopic visualization, allowing practitioners to precisely monitor and control the guide wires position under imaging, improving overall procedural accuracy.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical Surgicals' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.