Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS
Getein fPSA Fast Test Kit

Getein fPSA Fast Test Kit

Product Details:

  • Features Rapid, Reliable, High sensitivity, User friendly, Easy operation
  • Measurement Range 0.1-100 ng/mL
  • Display Type Requires separate immunofluorescence analyzer (not included)
  • Usage Type Single use
  • Storage Instructions Store at 4-30C, avoid sunlight and moisture
  • Accuracy >=95%
  • Shelf Life 18 months
  • Click to View more
X

Getein fPSA Fast Test Kit Price And Quantity

Getein fPSA Fast Test Kit Product Specifications

  • Single test cassette: Approx. 90 mm 20 mm 5 mm
  • >=95%
  • Store at 4-30C, avoid sunlight and moisture
  • Yes
  • Manual
  • Approx. 10 g per kit
  • Plastic, Paper, Chemical reagents
  • Detection of free Prostate-Specific Antigen (fPSA)
  • Yes
  • 18 months
  • Not required for strip; compatible with immunofluorescence analyzer
  • Diagnostic Test Kit
  • New
  • Medical Laboratory Instrument
  • White with blue labeling
  • Rapid, Reliable, High sensitivity, User friendly, Easy operation
  • In vitro quantitative determination of free Prostate-Specific Antigen (fPSA) in human serum and plasma
  • Immunofluorescence Assay
  • No
  • 0.1-100 ng/mL
  • Requires separate immunofluorescence analyzer (not included)
  • Single use

Product Description

Brand Getein Biotech
Sample Type Serum/ Plasma
Pack Size 25T
CAT No IF1072
Biomarker Tumor Marker

fPSA Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of free PSA in human serum and plasma samples. It is mainly used for dynamic monitoring of patients with malignant tumors to assist in judging the disease process or treatment effect. It cannot be used as a basis for early diagnosis of malignant tumors, and is not suitable for tumor screening in the general population. This assay is intended to be used in conjunction with the Getein total PSA test as an aid in distinguishing prostate cancer from benign prostatic conditions in men age 50 years or older who have a digital rectal examination (DRE) that is not suspicious for prostate cancer and the Getein total PSA value between 4 ng/mL and 10 ng/mL.



Rapid and Accurate Prostate Cancer Screening

The Getein fPSA Fast Test Kit offers a quick and precise solution for professional healthcare settings to screen and monitor prostate cancer. Its immunofluorescence assay technology ensures highly sensitive detection, supporting early diagnosis and improved patient outcomes within just 15 minutes.


User-Friendly and Portable Design

Engineered for ease of use, the single-use cassettes are lightweight and individually packaged, ideal for both permanent and mobile medical laboratories. No special power source is needed for the cassette, and the test's straightforward manual operation complements busy clinical environments.


Versatile and Reliable Clinical Application

Compatible with Getein1100, 1600, and 1700 analyzers, this test kit integrates seamlessly into diverse laboratory workflows. Its broad measurement range of 0.1-100 ng/mL and high accuracy make it a trustworthy tool for healthcare professionals in diagnosing and monitoring prostate conditions.

FAQ's of Getein fPSA Fast Test Kit:


Q: How does the Getein fPSA Fast Test Kit detect free Prostate-Specific Antigen (fPSA)?

A: The kit uses sandwich immunodetection paired with immunofluorescence assay technology to quantitatively determine fPSA levels in human serum or plasma, ensuring high sensitivity and reliability.

Q: What is the required sample volume, and how is the test performed?

A: A sample of 75 L of serum or plasma is needed. Apply the sample to the cassette and use the compatible Getein immunofluorescence analyzer. Results will be available within 15 minutes.

Q: When should this test be used in clinical practice?

A: It is suitable for clinical diagnosis, routine prostate cancer screening, and monitoring of patients with known prostate conditions as advised by a healthcare professional.

Q: Where should the Getein fPSA Fast Test Kits be stored?

A: Store the kits at 4-30C in a dry place, away from direct sunlight and moisture, to maintain optimal performance throughout the 18-month shelf life.

Q: What are the advantages of using this test kit in a healthcare setting?

A: This kit provides rapid, highly accurate, and quantitative results, supporting swift decision-making. It is user-friendly, portable, and integrates with Getein analyzers commonly found in laboratories.

Q: Is any special equipment required to read the results of the test?

A: Yes, while the cassette itself requires no power, results are displayed and analyzed using dedicated Getein immunofluorescence analyzers (Getein1100/1600/1700), which are not included with the kit.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical FIA' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.