Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS    Call Me Free
Mindray Total Thyroxine (CLIA) Mindray Total Thyroxine (CLIA) Mindray Total Thyroxine (CLIA)
Mindray Total Thyroxine (CLIA)
Mindray Total Thyroxine (CLIA) Mindray Total Thyroxine (CLIA)

Mindray Total Thyroxine (CLIA)

Product Details:

  • Usage Type Laboratory Diagnostic Use
  • Measurement Range 0.524 g/dL (value may vary by analyzer model)
  • Shelf Life 12 months
  • Accuracy Within manufacturers specifications (typically CV 10%)
  • Features High sensitivity, specificity, suitable for Mindray CL series analyzers
  • Instruments Type For use with Mindray CL series analyzers
  • Storage Instructions 28C, avoid freezing
  • Click to View more
X

Mindray Total Thyroxine (CLIA) Price And Quantity

  • CL-900i, CL-1000i, CL-2000i, and other Mindray CL analyzers
  • Provided with kit or available separately
  • Chemiluminescent competitive immunoassay
  • 100 tests per kit (varies by pack size/region)
  • Human serum or plasma
  • ~25 minutes (varies based on Mindray system version)
  • IVD (In Vitro Diagnostic) use

Mindray Total Thyroxine (CLIA) Product Specifications

  • Measures total thyroxine (TT4) concentration in serum/plasma
  • No
  • White (box)
  • Automated
  • Chemiluminescence Immunoassay (CLIA)
  • 28C, avoid freezing
  • Diagnostic Reagent
  • High sensitivity, specificity, suitable for Mindray CL series analyzers
  • For use with Mindray CL series analyzers
  • CLIA Reagent Kit
  • Yes
  • Quantitative determination of total thyroxine (TT4) in human serum or plasma
  • Within manufacturers specifications (typically CV 10%)
  • No
  • 0.524 g/dL (value may vary by analyzer model)
  • 12 months
  • New
  • Laboratory Diagnostic Use
  • CL-900i, CL-1000i, CL-2000i, and other Mindray CL analyzers
  • Provided with kit or available separately
  • Chemiluminescent competitive immunoassay
  • 100 tests per kit (varies by pack size/region)
  • Human serum or plasma
  • ~25 minutes (varies based on Mindray system version)
  • IVD (In Vitro Diagnostic) use

Product Description

Brand Mindray

Sample Type Serum

Pack Size 2 x 50T, 2 x 100T

CAT No 10500421100, 10500423800

Application Immuno-Assay

Ourchemiluminescence immunoassay reagentshave been specially developed to work with Mindray's CL series automatic chemiluminescence immunoassay analyzers to make a complete system, offering high reliability and accuracy. Mindray uses liquid, ready-to-use reagents which come in two packages, 50 tests and 100 tests, to suit customers with different requirements.



Advanced Quantification of Thyroxine

This kit allows laboratories to quantitatively assess total thyroxine (TT4) levels in human serum or plasma with precision. By using a chemiluminescent competitive immunoassay method, it delivers reliable and highly specific results for thyroid function evaluation.


Optimized for Mindray Analyzer Platforms

The reagent kit is tailored for seamless integration with Mindray CL series analyzers (including CL-900i, CL-1000i, CL-2000i), ensuring automated workflow and accurate analytical performance within minutes, making it a practical choice for high-throughput clinical labs.


Reliable Performance and Flexible Packaging

Each kit supports 100 tests, with calibrators and controls included or independently available. It is built to comply with IVD standards, maintains a 12-month shelf life under recommended storage, and provides consistently accurate results across a broad measurement range.

FAQ's of Mindray Total Thyroxine (CLIA):


Q: How does the Mindray Total Thyroxine (CLIA) kit measure thyroxine levels?

A: The Mindray Total Thyroxine (CLIA) kit utilizes a chemiluminescent competitive immunoassay technique to quantitatively determine total thyroxine (TT4) concentrations in human serum or plasma samples.

Q: What is the intended sample type for this reagent kit?

A: This kit is intended for use with human serum or plasma samples, offering accurate TT4 measurement suitable for laboratory diagnostic purposes.

Q: When should calibrators and controls be used with this kit?

A: Calibrators and controls should be run according to laboratory protocols and manufacturer recommendations, typically with each new kit or analyzer run, to ensure reliable and accurate test results.

Q: Where can this reagent kit be used and on which analyzers?

A: The Mindray Total Thyroxine (CLIA) kit is designed for laboratory use and is compatible with Mindray CL-900i, CL-1000i, CL-2000i, and other compatible CL analyzers.

Q: What is the typical reaction time for a test on this system?

A: The average reaction time for TT4 measurement using this kit is approximately 25 minutes, although this may vary slightly depending on the specific Mindray system model used.

Q: How should the kit be stored to maintain stability and performance?

A: Store the kit at 2-8C and avoid freezing to ensure the reagents remain effective throughout the 12-month shelf life.

Q: What are the main benefits of using the Mindray Total Thyroxine (CLIA) kit in laboratories?

A: The kit offers high sensitivity and specificity, rapid results, automated workflow, and reliable performance for quantitative thyroxine testing, making it ideal for clinical laboratories aiming for efficiency and accuracy.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical Reagents' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.