Product Details:

  • Features High sensitivity and specificity, ready-to-use, compatible with MAGLUMI series analyzers
  • Usage Type Clinical Laboratory
  • Instruments Type Clinical Chemistry Laboratory Analyzer Kit
  • Storage Instructions Store at 2-8C, avoid freezing
  • Shelf Life 12 months from date of manufacture
  • Function Total IgE quantification
  • Measurement Range 23000 IU/mL
  • Click to View more
X

Snibe MAGLUMI IgE (CLIA) Price And Quantity

Snibe MAGLUMI IgE (CLIA) Product Specifications

  • Clinical Laboratory
  • High sensitivity and specificity, ready-to-use, compatible with MAGLUMI series analyzers
  • No
  • For quantitative determination of IgE in human serum or plasma
  • N/A (Kit only)
  • N/A (Kit only)
  • Diagnostic reagent, sealed vial
  • N/A (Kit only)
  • Total IgE quantification
  • New
  • N/A (Kit only)
  • No
  • 12 months from date of manufacture
  • Clear/Colorless Reagent
  • Chemiluminescence Immunoassay (CLIA)
  • Store at 2-8C, avoid freezing
  • Clinical Chemistry Laboratory Analyzer Kit
  • 95%
  • N/A (Kit only)
  • Automated
  • Compatible with MAGLUMI platform
  • Maglumi Immunoassay Analyzer Reagent Kit
  • Yes
  • 23000 IU/mL
  • Available
  • Up to 180 tests/hour (on MAGLUMI analyzer)
  • CE marked
  • Human serum or plasma
  • 50 L
  • Qualitative and quantitative measurement of total immunoglobulin E (IgE)
  • Within 30 minutes
  • Ready-to-use liquid reagents
  • Internal and external controls recommended
  • Up to 4 weeks per calibration
  • Two-site sandwich immunoassay

Product Description

Brand Snibe
Sample Type Serum
Pack Size 100T
CAT No. 130258001M
Application Infection

The kit has been designed for the quantitative determination of Immunoglobulin E (IgE) in human serum. The method can be used for samples over the range of 0-3200 IU/ml. The test has to be performed on the MAGLUMI chemiluminescence immunoassay (CLIA) fully auto analyzer (Including MAGLUMI 1000, MAGLUMI 2000, MAGLUMI 2000 Plus and new developed models).



High-Efficiency Diagnostic Performance

Achieve fast and reliable quantification of total IgE with the MAGLUMI IgE (CLIA) kit, designed for high-throughput laboratory environments. Its advanced chemiluminescence technology and two-site sandwich immunoassay allow for accurate results across a broad measurement range, supporting both routine and urgent clinical diagnostics.


User-Friendly, Ready-to-Use Reagents

Save valuable laboratory time with ready-to-use, liquid reagents that require no preparation. The kit is sealed for convenience and optimal preservation. Each batch features lot traceability, enhancing confidence and accountability in every test run, while internal and external quality controls ensure consistent accuracy.


Comprehensive Support for Clinical Applications

Designed for use on the MAGLUMI Immunoassay Analyzer, this kit is ideal for laboratories performing allergy and immunological screening. Results are delivered within 30 minutes, supporting timely decision-making and improved patient care. International quality standards are met with CE marking and a 12-month shelf life.

FAQ's of Snibe MAGLUMI IgE (CLIA):


Q: How does the MAGLUMI IgE (CLIA) kit perform the measurement of total IgE?

A: The kit utilizes a two-site sandwich immunoassay based on chemiluminescence technology. It detects and quantifies total immunoglobulin E (IgE) in human serum or plasma, delivering results through the MAGLUMI analyzer.

Q: What sample type and volume are required for the test?

A: A minimum of 50 L of human serum or plasma is required for each test, making it minimally invasive and suitable for a variety of clinical settings.

Q: What is the typical turnaround time for test results using this kit?

A: The Snibe MAGLUMI IgE (CLIA) kit provides results within 30 minutes, allowing rapid diagnosis and timely intervention.

Q: Where can the MAGLUMI IgE (CLIA) kit be used?

A: This reagent kit is intended for use in clinical laboratories with access to the MAGLUMI Immunoassay Analyzer series. It is not designed for at-home or point-of-care testing.

Q: What are the storage requirements for maintaining reagent stability?

A: Reagents should be stored between 2-8C and should not be frozen, ensuring optimal performance and a shelf life of 12 months from the date of manufacture.

Q: How often does the calibration need to be performed?

A: Calibration remains stable for up to 4 weeks per lot, reducing downtime and maintenance efforts for laboratory personnel.

Q: What are the key benefits of using this kit for total IgE quantification?

A: The kit offers high accuracy (95%), high throughput (up to 180 tests/hour), and a broad measurement range (2-3000 IU/mL). Its ready-to-use format, quality assurance, and regulatory compliance make it a reliable choice for clinical laboratories.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical CLIA' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.