Product Details:

  • Automation Grade Fully automated
  • Measurement Range Wide dynamic range: 10 g/L up to 10,000 mg/L (liquid samples), <1 ppm up to % (solid samples), depending on element
  • Frequency 50/60 Hz
  • Voltage 220240 V
  • Capacity Up to 31 position autosampler (liquid), up to 120 positions (solid)
  • Core Components High-performance NDIR detectors, UV photometer, advanced autosampler, combustion furnace
  • Model No Multi EA 5100
  • Click to View more
X

Analytikjena Multi EA 5100 for Micro-Elemental Analysis Price And Quantity

  • Automatic multi-point calibration; supports multiple calibration curves
  • Internal memory and external export via software
  • Leak detection, over-temperature protection, corrosion resistant components, automatic shutdown
  • Vertical and horizontal combustion modes switchable without hardware modification
  • Temperature: +5C to +40C, Humidity: up to 80% non-condensing
  • Meets international standards such as ASTM, EPA, ISO, DIN, and others
  • Total Carbon (TC), Total Organic Carbon (TOC), Total Nitrogen (TN), Total Sulfur (TS), Total Chlorine (TX/Cl), AOX, EOX, POX, and more
  • Oxygen: typically 30300 ml/min (application dependent)
  • Modular system for extension with extra detectors and modules
  • Automatic, manual, or with versatile autosamplers for both liquid and solid
  • Advanced High Temperature Catalytic Combustion and UV Fluorescence/NDIR/ Micro-coulometric detection (depending on parameter)
  • Oxygen (standard), with adaptors available for use of argon or synthetic air as protective/carrier gases
  • USB/Ethernet PC connectivity, multi-language software support

Analytikjena Multi EA 5100 for Micro-Elemental Analysis Product Specifications

  • Up to 1,500C combustion temperature
  • Approx. 42 kg
  • Superior precision: 1% RSD for repeated measurements (matrix dependent)
  • Micro-Elemental Analyzer (multiparameter analyzer: C, N, S, Cl, TOC, TX, AOX, EOX, POX)
  • Laboratory elemental analysis of solids, liquids, gases, gases in LPG, and special samples
  • Fully automated, vertical/horizontal operation modes, multi-matrix application, quick changeover, maintenance-friendly design, minimal sample preparation
  • Multi EA 5100
  • 220240 V AC
  • High-performance NDIR detectors, UV photometer, advanced autosampler, combustion furnace
  • Up to 31 position autosampler (liquid), up to 120 positions (solid)
  • 220240 V
  • 50/60 Hz
  • Corrosion-resistant stainless steel, specialized quartz glass
  • 590 x 480 x 515 mm
  • Wide dynamic range: 10 g/L up to 10,000 mg/L (liquid samples), <1 ppm up to % (solid samples), depending on element
  • 7 inch color LCD touchscreen display
  • Fully automated
  • Automatic multi-point calibration; supports multiple calibration curves
  • Internal memory and external export via software
  • Leak detection, over-temperature protection, corrosion resistant components, automatic shutdown
  • Vertical and horizontal combustion modes switchable without hardware modification
  • Temperature: +5C to +40C, Humidity: up to 80% non-condensing
  • Meets international standards such as ASTM, EPA, ISO, DIN, and others
  • Total Carbon (TC), Total Organic Carbon (TOC), Total Nitrogen (TN), Total Sulfur (TS), Total Chlorine (TX/Cl), AOX, EOX, POX, and more
  • Oxygen: typically 30300 ml/min (application dependent)
  • Modular system for extension with extra detectors and modules
  • Automatic, manual, or with versatile autosamplers for both liquid and solid
  • Advanced High Temperature Catalytic Combustion and UV Fluorescence/NDIR/ Micro-coulometric detection (depending on parameter)
  • Oxygen (standard), with adaptors available for use of argon or synthetic air as protective/carrier gases
  • USB/Ethernet PC connectivity, multi-language software support

Product Description

Brand

Analytikjena

Model

EA 5100

Capacity

Gas: up to 200 Bar, LPG: up to 35 Bar

CAT No

450-300.011

Application

Elemental Analyzer

The multi EA 5100 is your flexible all-rounder for sulfur, nitrogen, chlorine, and carbon analysis in solids, liquids, and gases. Benefit from the combination of outstanding robustness and sensitivity, best service, and cost-effective high-throughput analysis in every matrix in QC laboratories, in research, or in contract analysis.



Advanced Multi-Matrix Elemental Analysis

The Multi EA 5100 excels in analyzing diverse sample types-including solids, liquids, gases, and LPG-across industries. Its fully automated sample introduction and versatile autosamplers streamline workflows for high-throughput laboratories. The instrument supports both vertical and horizontal combustion modes, enabling rapid switching between applications without any hardware modifications. With robust detection technologies, it ensures accurate determination of a wide range of elements even in complex matrices.


Reliable Performance and Compliance

Engineered for precision, the Multi EA 5100 delivers stable and reproducible results-with repeatability as low as 1% RSD depending on the matrix. The analyzer meets major international standards (ASTM, EPA, ISO, DIN), ensuring your laboratory analysis passes regulatory requirements. State-of-the-art safety features and corrosion-resistant components safeguard both operators and equipment, even under continuous operation in demanding environments.


User-Friendly Operation and Expandability

A 7-inch color LCD touchscreen provides intuitive operation with multi-language software support. The instrument's modular architecture allows for the extension of extra detectors and modules as laboratory needs grow. Automated calibration, ample data storage, seamless PC connectivity, and quick changeover between modes facilitate routine analysis while minimizing downtime and manual intervention.

FAQ's of Analytikjena Multi EA 5100 for Micro-Elemental Analysis:


Q: How does the Analytikjena Multi EA 5100 detect and measure multiple elements in various sample types?

A: This analyzer uses advanced high-temperature catalytic combustion, combined with several detection methods such as UV fluorescence, NDIR, and micro-coulometric detection. It can process a range of matrices-including solids, liquids, and gases-by employing automatic or manual sample introduction and versatile autosamplers. Measurements include elements like C, N, S, Cl, and organohalogen compounds, ensuring comprehensive elemental analysis within a single platform.

Q: What international standards does the Multi EA 5100 comply with for laboratory analysis?

A: The Multi EA 5100 is fully compliant with prominent international standards such as ASTM, EPA, ISO, and DIN. This guarantees that your analytical results are accepted in regulated environments, providing confidence in data quality during audits and certification processes.

Q: When should I use vertical or horizontal combustion modes on the Multi EA 5100?

A: You can switch between vertical and horizontal combustion modes depending on sample type and analytical requirements. Vertical mode is particularly suited for handling liquid and volatile samples, minimizing loss, while horizontal mode is often used for solid samples. The transition between modes is quick and does not require hardware modification, offering flexibility for diverse laboratory workflows.

Q: Where is the Multi EA 5100 typically applied, and what kind of laboratories benefit most from its capabilities?

A: The analyzer is ideal for research and quality control laboratories across industries such as environmental, petrochemical, pharmaceutical, chemical manufacturing, and academic research. Laboratories that require rapid, reliable analysis of micro-elements in solid, liquid, or gaseous samples gain the most from the system's automation, wide measurement ranges, and compliance credentials.

Q: How does automated calibration and detection enhance analytical accuracy and throughput?

A: The Multi EA 5100 features automatic multi-point calibration and supports multiple calibration curves. Together with automated sample handling and robust detectors, these features reduce errors, ensure consistent accuracy (1% RSD), and boost throughput-allowing laboratories to analyze larger sample volumes with minimal operator intervention.

Q: What are the key benefits of the Multi EA 5100's safety and maintenance features?

A: The system incorporates leak detection, over-temperature protection, corrosion-resistant materials, and automatic shutdown functions, promoting safe operation even with challenging samples. Its maintenance-friendly design, modular components, and quick-change operation minimize downtime and simplify routine maintenance.

Q: What options are available for data storage, connectivity, and software usability with the Multi EA 5100?

A: The analyzer offers internal memory, easy data export via dedicated software, USB/Ethernet connectivity, and user-friendly multi-language software. Its 7-inch color touchscreen makes operation straightforward, facilitating data management and integration with laboratory information systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Life Sciences' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.