Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS
Snibe MAGLUMI HBsAg (CLIA) Snibe MAGLUMI HBsAg (CLIA) Snibe MAGLUMI HBsAg (CLIA) Snibe MAGLUMI HBsAg (CLIA) Snibe MAGLUMI HBsAg (CLIA) Snibe MAGLUMI HBsAg (CLIA)
Snibe MAGLUMI HBsAg (CLIA)
Snibe MAGLUMI HBsAg (CLIA) Snibe MAGLUMI HBsAg (CLIA) Snibe MAGLUMI HBsAg (CLIA) Snibe MAGLUMI HBsAg (CLIA) Snibe MAGLUMI HBsAg (CLIA)

Snibe MAGLUMI HBsAg (CLIA)

Product Details:

  • Usage Type Laboratory
  • Accuracy High diagnostic accuracy, as per Snibe specifications
  • Shelf Life 12 months from manufacturing date
  • Display Type Not Applicable (uses analyzer display)
  • Function Screening and diagnosis of Hepatitis B surface antigen
  • Storage Instructions Store at 28C (refrigerated)
  • Features High sensitivity, specificity, and fully automated compatibility
  • Click to View more
X

Snibe MAGLUMI HBsAg (CLIA) Price And Quantity

Snibe MAGLUMI HBsAg (CLIA) Product Specifications

  • Yes
  • Not Applicable (uses analyzer display)
  • As supplied (kit components, generally white/transparent)
  • No
  • Laboratory
  • High sensitivity, specificity, and fully automated compatibility
  • CLIA (Chemiluminescence Immunoassay)
  • Chemiluminescence Immunoassay (CLIA) Analyzer Reagent
  • Store at 28C (refrigerated)
  • As per manufacturers reagent kit size
  • 12 months from manufacturing date
  • Not Applicable (Reagent)
  • No
  • High diagnostic accuracy, as per Snibe specifications
  • New
  • Screening and diagnosis of Hepatitis B surface antigen
  • Detection of Hepatitis B Surface Antigen (HBsAg) in human serum or plasma
  • Automated
  • Clinical Laboratory Reagent
  • As per analyzer protocol; qualitative assay
  • As per reagent pack size
  • Diagnostic Reagent (kit), plastic cartridge
  • Typically within 30 minutes
  • Acridinium ester chemiluminescence immunoassay
  • Depends on analyzer (example: up to 180 tests/hour with MAGLUMI 800)
  • MAGLUMI series CLIA analyzers (e.g., MAGLUMI 800, 1000, 2000)
  • Ready-to-use reagents, calibrators, controls, instructions for use
  • Reagents ready to use, no manual mixing required
  • Each kit batch/lots traceable
  • Serum or plasma

Product Description

Brand Snibe
Sample Type Serum
Pack Size 100T
CAT No. 130210009M
Application Infection

Hepatitis B surface antigen (HBsAg) in human serum.
The test has to be performed on MAGLUMI Fully-auto chemiluminescence immunoassay (CLIA) analyzer (Including Maglumi 600, Maglumi 800, Maglumi 1000, Maglumi 1000 Plus, Maglumi 2000, Maglumi 2000 Plus, Maglumi 4000 and Maglumi 4000 Plus).



Advanced CLIA Technology for HBsAg Detection

Utilizing acridinium ester chemiluminescence immunoassay, the MAGLUMI HBsAg kit ensures superior analytical performance in the screening and diagnosis of hepatitis B infections. Its compatibility with the fully automated MAGLUMI analyzers results in faster turnaround times and reduced manual workload for laboratories.


Ready-to-Use Convenience and High Throughput

The kit's ready-to-use components eliminate the need for any manual reagent preparation, streamlining daily laboratory operations. With the ability to process up to 180 samples per hour on the MAGLUMI 800 analyzer, it meets the demands of high-volume clinical settings while maintaining accuracy and reliability.

FAQ's of Snibe MAGLUMI HBsAg (CLIA):


Q: How do I use the Snibe MAGLUMI HBsAg (CLIA) reagent kit in my laboratory?

A: Simply load the ready-to-use reagents, calibrators, and controls onto a compatible MAGLUMI CLIA analyzer, such as the MAGLUMI 800, 1000, or 2000. No manual mixing or preparation is required, and the automated analyzer guides the entire testing process.

Q: What types of samples can be tested with this kit?

A: The MAGLUMI HBsAg (CLIA) kit is validated for use with human serum or plasma samples, ensuring versatility across a variety of clinical laboratory needs.

Q: When can I expect test results after starting the analysis?

A: Typically, the MAGLUMI HBsAg assay provides results within 30 minutes of sample loading, enabling rapid clinical decision-making and prompt patient management.

Q: Where should the reagent kit be stored, and what is its shelf life?

A: Store all kit components at 2-8C (refrigerated) as recommended by the manufacturer. The shelf life is 12 months from the manufacturing date, preserving reagent integrity and performance.

Q: What are the benefits of using this CLIA kit for HBsAg detection?

A: The kit offers high sensitivity and specificity, fully automated processing, traceability for quality assurance, and the potential for high-throughput screening-making it ideal for busy clinical laboratories requiring reliable and consistent results.

Q: Is any manual reagent preparation required before running tests?

A: No manual mixing or preparation is necessary. All reagents, calibrators, and controls are supplied ready-to-use to minimize hands-on time and reduce the risk of errors.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical CLIA' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.