Product Description
| Brand |
Snibe |
| Sample Type |
Serum |
| Pack Size |
100T |
| CAT No. |
130203009M |
| Application |
Thyroid Marker |
The kit has been designed for the quantitative determination of TSH receptor antibodies (TRAb) in human serum. The method can be used for samples over the range of 2.5-300.0IU/ml. The test has to be performed on the Fully-auto chemiluminescence immunoassay (CLIA) analyzer MAGLUMI (Including Maglumi 600,Maglumi 1000,Maglumi 1000 Plus, Maglumi 2000,Maglumi 2000 Plus,Maglumi 3000 and Maglumi 4000).
Accurate Diagnosis for Thyroid DiseasesThe SNIBE MAGLUMI TRAb (CLIA) enables laboratories to reliably detect and quantify TSH receptor antibodies, supporting accurate diagnosis and monitoring of Graves' disease and related autoimmune thyroid conditions. Its high sensitivity and specificity ensure dependable results for clinicians.
User-Friendly Automated WorkflowDesigned for use with MAGLUMI series analyzers, this reagent kit offers a one-step, fully automatic process with random access capabilities. The ready-to-use format minimizes handling errors and streamlines laboratory operations, while the short reaction time enhances throughput.
Comprehensive Kit Contents and Reliable PerformanceEach kit includes diagnostic-grade reagents, calibrators, and control material, ensuring a complete solution for quantitative TRAb analysis. The kit is CE marked, conforming to international standards for laboratory diagnostics and is suitable for a wide range of laboratory settings.
FAQ's of Snibe MAGLUMI TRAb (CLIA):
Q: How does the SNIBE MAGLUMI TRAb (CLIA) kit work?
A: This kit utilizes a one-step competitive chemiluminescence immunoassay (CLIA) method to quantitatively detect thyroid-stimulating hormone receptor antibodies (TRAb) in human serum, aiding in the diagnosis of autoimmune thyroid diseases such as Graves' disease.
Q: What are the benefits of using this assay for TRAb detection?
A: The assay delivers high sensitivity and specificity, providing accurate and reliable results with minimal manual intervention. It is fully automated when used with the MAGLUMI analyzer series, reducing workflow complexity and minimizing the risk of errors.
Q: When should the SNIBE MAGLUMI TRAb (CLIA) be used?
A: Use this reagent kit in cases where quantitative measurement of TRAb is required, particularly for diagnosing Graves' disease or other related autoimmune thyroid disorders in human serum samples.
Q: What sample volume is needed and how fast are the results?
A: Only 20 L of human serum is required per test. The reaction is completed in approximately 30 minutes, making it suitable for laboratories needing rapid turnaround times.
Q: Where can this kit be used and by whom?
A: The kit is designed for use in professional laboratory settings equipped with compatible MAGLUMI series automated immunoassay analyzers. It is suitable for use by trained laboratory personnel.
Q: What steps are involved in the testing process?
A: After loading the ready-to-use reagents, calibrators, and controls into the analyzer, the system automatically performs the assay using your serum sample. Calibration is performed using a two-point master curve, and the process is fully automated, requiring minimal manual intervention.
Q: How should the kit be stored to maintain reagent stability?
A: Store the entire kit at 2-8C, protected from light. Under these conditions, the reagents remain stable for up to 12 months as indicated by the manufacturer.