Product Description
| Snibe |
| Sample Type |
Serum |
| Pack Size |
100T |
| CAT No. |
130213002M |
| Application |
Anemia Marker |
The kit has been designed for the quantitative determination of Vitamin B12 in human serum. The method can be used for samples over the range of 50.0-2000.0pg/ml. The test has to be performed on the Fully-auto chemiluminescence immunoassay (CLIA) analyzer MAGLUMI (Including Maglumi 600,Maglumi 1000,Maglumi 1000 Plus, Maglumi 2000,Maglumi 2000 Plus, Maglumi 3000 and Maglumi 4000).
Advanced CLIA Technology for Precise B12 QuantificationHarnessing the power of chemiluminescent immunoassay, the MAGLUMI Vitamin B12 kit ensures reproducible and traceable results with a measurement range from 50-2000 pg/mL. The competitive immunoassay format and integrated calibration system work together to deliver high-accuracy performance within a short incubation time of about 35 minutes.
User-Friendly and Fully Automated ProcessOptimized for the MAGLUMI CLIA series analyzers, the reagent kit offers seamless, fully automatic operation. Simply load the kit into your compatible Snibe analyzer and start the quantitative testing process-no manual intervention is required, creating a streamlined workflow ideal for high-throughput laboratories.
Reliability and Quality AssuranceThe kit includes multi-level calibrators as well as built-in quality controls, providing reliable accuracy for each batch of tests. With a shelf life of 12 months and strict storage guidelines (2-8C), laboratories can maintain consistent performance and compliance with stringent diagnostic standards.
FAQ's of Snibe MAGLUMI Vitamin B12 (CLIA):
Q: How do I use the Snibe MAGLUMI Vitamin B12 (CLIA) reagent kit with my analyzer?
A: The kit is specifically designed for use with the MAGLUMI Series analyzers from Snibe. Simply load the reagent bottles as instructed in your analyzer's protocol. The process is fully automatic - once the sample and reagents are in place, the analyzer will run the test and provide results via luminescence detection.
Q: What sample types are required for this Vitamin B12 test kit?
A: The Snibe MAGLUMI Vitamin B12 (CLIA) reagent kit accepts either serum or plasma samples. Ensure samples are prepared following standard laboratory protocols for in-vitro diagnostics.
Q: When should the calibration and quality control be performed?
A: Calibration using the multi-level calibrators provided should be performed according to your instrument's recommended schedule-typically before running a new batch or when a new kit is opened. Quality control should be run regularly to ensure the continued reliability of your results.
Q: Where should the reagent kit be stored, and what is its shelf life?
A: Store the kit at a temperature between 2-8C. Each kit comes with a 12-month shelf life, allowing for flexible and reliable usage in clinical environments.
Q: What benefits does this kit offer over other Vitamin B12 assays?
A: The MAGLUMI Vitamin B12 kit provides rapid results (about 35 minutes), high sensitivity, traceable calibration, and robust quality control, making it ideal for busy clinical labs demanding accuracy and reproducibility.
Q: What is the process for quantifying Vitamin B12 using this kit?
A: After loading the sample and reagents into the analyzer, the system performs a competitive immunoassay at 37C. The reaction's luminescent signal is measured, and Vitamin B12 concentration is quantified within a range of 50-2000 pg/mL.
Q: Is the kit suitable for portable or point-of-care setups?
A: No, the kit is not portable. It is specifically intended for use in laboratories equipped with the MAGLUMI series analyzers. The reagent bottles must be run using the automated analyzer for accurate and reliable results.