Product Details:

  • Capacity Standard 100 samples tray
  • Core Components NexSAR HPLC, Autosampler, Degasser, Pump module, Column Oven, Software
  • Frequency 50/60 Hz
  • Model No NexSAR Speciation Analysis System
  • Measurement Range Low ppb to high ppm analyte concentrations
  • Temperature Range Ambient +4°C to 60°C
  • Accuracy ±0.5% RSD
  • Click to View more
X

PerkinElmer NexSAR Speciation Analysis Ready HPLC System Price And Quantity

PerkinElmer NexSAR Speciation Analysis Ready HPLC System Product Specifications

  • Fully integrated and ready for full speciation workflows
  • Ambient +4°C to 60°C
  • ±0.5% RSD
  • Corrosion-resistant stainless steel and specialized polymers
  • Low ppb to high ppm analyte concentrations
  • Elemental and species-specific chromatography analysis
  • AC Mains
  • Fully Automated
  • 100-240 V AC
  • Approximately 62 kg
  • HPLC System for Speciation Analysis
  • Standard 100 samples tray
  • NexSAR HPLC, Autosampler, Degasser, Pump module, Column Oven, Software
  • LCD Touchscreen Interface
  • 670 x 405 x 600 mm
  • 50/60 Hz
  • NexSAR Speciation Analysis System
  • Compatible with all standard HPLC columns
  • ClarityChrom CDS with dedicated speciation workflows
  • Quaternary low-pressure gradient pump
  • <55 dB (operational)
  • up to 6000 psi (414 bar)
  • 15°C to 35°C, max 80% RH
  • Digital, USB and Ethernet connectivity
  • Multi-mode (UV/Vis, ICP-MS, and conductivity detectors supported)
  • 0.1 µL to 100 µL
  • Leak sensor, overpressure protection, automatic shutdown
  • High throughput, ideal for routine and research labs

Product Description

Brand

PerkinElmer

Model

NexSAR

Capacity

Three-channel NexSAR Degasser and Solvent Tray

CAT No

N8150506

Application

Chromatography

The NexSAR HPLC, is a next-generation Speciation Analysis Ready system engineered with a completely inert and metal-free fluid path, enabling laboratories to meet low chromatographic background requirements on the most challenging speciation applications. Plus, it is fully customizable, with the flexibility to select only the parts that you need for your application(s).




Advanced Speciation Analysis for Relentless Precision

Engineered for high sensitivity and reliability, the NexSAR HPLC Speciation Analysis System is perfect for labs seeking versatile and accurate elemental speciation. Its multi-mode detection and robust automation support a wide scope of research and regulatory applications, efficiently processing large sample volumes while maintaining precision even at low ppb levels.


Intuitive Automation and Software Integration

The fully integrated ClarityChrom CDS software simplifies complex workflows, reducing operator intervention and enhancing productivity. Automated features such as quaternary gradient pumping, autosampling, and column oven management ensure reproducible results and maximized instrument uptime for seamless laboratory operations.


Durable Construction and Flexible Operation Environment

Made with corrosion-resistant stainless steel and specialized polymers, the NexSAR can withstand demanding lab conditions. It operates within a broad ambient temperature range, fits within compact lab spaces, and maintains a low operational noise level for user comfort. Comprehensive safety systems further protect the system and users during unattended runs.

FAQ's of PerkinElmer NexSAR Speciation Analysis Ready HPLC System:


Q: How does the NexSAR HPLC system enhance elemental speciation analysis in laboratories?

A: The NexSAR HPLC system streamlines elemental and species-specific chromatographic analysis with high sensitivity and precision, supporting multi-mode detection (UV/Vis, ICP-MS, and conductivity), which allows for comprehensive identification and quantification of analytes across a broad concentration range from low ppb to high ppm.

Q: What is the process for setting up and using the NexSAR Speciation Analysis System?

A: Simply install the core components-autosampler, degasser, pump, and column oven-connect via USB or Ethernet, and follow the stepwise guidance in ClarityChrom CDS. The fully automated system enables users to load up to 100 samples, configure analysis methods, and initiate runs with minimal manual handling, ensuring fast and reproducible workflow execution.

Q: When is it recommended to utilize the system's multi-mode detection capability?

A: Multi-mode detection is recommended when detailed element and species information is required, such as in regulatory compliance, food safety, environmental monitoring, or research settings. The system seamlessly switches between UV/Vis, ICP-MS, and conductivity detectors based on specific analytical requirements.

Q: Where can the NexSAR HPLC system be deployed for optimal usage?

A: The system is ideal for both routine analytical and research laboratories, including commercial, academic, pharmaceutical, and environmental facilities. Its compact dimensions and ambient operating range of 15C to 35C (up to 80% RH) allow for flexible placement in diverse lab environments throughout India.

Q: What are the key benefits of using ClarityChrom CDS with the NexSAR system?

A: ClarityChrom CDS provides intuitive control over the entire system, incorporating dedicated speciation workflows, automated data acquisition, and powerful result interpretation tools. It increases lab productivity and ensures compliance with reporting standards while minimizing user error.

Q: How does the system ensure user and instrument safety during operation?

A: Safety features include an integrated leak sensor, overpressure protection, and automatic shutdown mechanisms that prevent accidents. These safeguards ensure continuous, unattended operation by protecting both users and sensitive instrument components.

Q: What types of columns and sample types are compatible with the NexSAR HPLC system?

A: NexSAR is compatible with all standard HPLC columns, making it highly flexible for various applications. It supports a wide spectrum of sample types, from environmental and food matrices to pharmaceuticals, enabling comprehensive analysis of elements and their species.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Life Sciences' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.