Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS    Call Me Free
Eppendorf Centrifuge 5810 - Benchtop Centrifuge (Rotor A-4-62)

Eppendorf Centrifuge 5810 - Benchtop Centrifuge (Rotor A-4-62)

Product Details:

  • Voltage 230 V / 50-60 Hz
  • Usage Sample separation and pelleting
  • Weight Approx. 76 kg (with rotor)
  • Operate Method Digital control with LCD display
  • Classification Laboratory Equipment
  • Application Clinical, Research and Industrial Laboratories
  • Power Single-phase supply, 1000 W
  • Click to View more
X

Eppendorf Centrifuge 5810 - Benchtop Centrifuge (Rotor A-4-62) Price And Quantity

Eppendorf Centrifuge 5810 - Benchtop Centrifuge (Rotor A-4-62) Product Specifications

  • 4 x 400 ml (with Rotor A-4-62)
  • 76 cm x 65 cm x 34 cm
  • Benchtop Centrifuge
  • White/Grey
  • Digital control with LCD display
  • Clinical, Research and Industrial Laboratories
  • Laboratory Equipment
  • Sample separation and pelleting
  • 230 V / 50-60 Hz
  • Approx. 76 kg (with rotor)
  • High-quality plastic and metal
  • Single-phase supply, 1000 W

Product Description

Brand Eppendorf
Model 5810 (Rotor A-4-62)
Capacity 20,913 x g
CAT No 5810000320
Application Centrifuge

Centrifuge 5810, with its renowned quality and reliability, offers you the most cost-effective solution for medium to high-throughput applications requiring speeds of up to 20,913 x g (14,000 rpm). This benchtop centrifuge has been designed to fit into every lab and make routine work more comfortable thanks to its quiet operation, soft-touch lid closure and low access height for easy loading and unloading.



Powerful Performance for Versatile Applications

The Eppendorf Centrifuge 5810 supports laboratories in efficiently processing various sample types, from blood to tissue and liquid samples. With a maximum speed of 4,000 rpm and a high RCF, it is well-suited for pelleting and separation tasks in clinical, research, and industrial settings. Its generous 4 x 400 ml capacity enhances productivity for high-throughput operations.


User-Friendly Digital Control and Safety Features

Navigating operations is straightforward with a modern LCD digital display and programmable cycles. Automatic lid locking, imbalance detection, and emergency lid release provide robust safety, while the low noise operation (<60 dB(A)) ensures a comfortable laboratory environment. Its precise digital timer (1-99 min or continuous) suits varied protocol requirements.


Reliable Build and Practical Design

Manufactured from high-quality plastic and metal, the centrifuge offers both durability and dependable performance. Designed for benchtop use, its compact white/grey body fits seamlessly into laboratories. The unit's streamlined aspect and swing-bucket rotor help accommodate various workflows, ensuring consistent separation and sample quality.

FAQ's of Eppendorf Centrifuge 5810 - Benchtop Centrifuge (Rotor A-4-62):


Q: How do I operate the Eppendorf Centrifuge 5810 and set the desired cycle?

A: Operation is user-friendly-use the LCD digital display to program speed, time (1-99 minutes or continuous run), and cycle parameters. After loading your samples and securing the lid, simply select your desired settings and start the run using the digital controls.

Q: What types of samples are compatible with the Rotor A-4-62 in this centrifuge?

A: The Rotor A-4-62 swing-bucket rotor supports a wide range of sample types, including blood, cell suspensions, tissue samples, and various liquids, making it ideal for both clinical diagnostics and research applications.

Q: When should I use the programmable operation cycles feature?

A: Programmable cycles are useful when standardizing procedures across multiple runs, or when specific protocols require precise timing and speed. This function improves workflow efficiency and consistency in routine laboratory operations.

Q: Where is the Eppendorf Centrifuge 5810 commonly used?

A: This model is widely used in clinical labs, research institutes, and industrial laboratories throughout India and internationally, especially wherever large-capacity sample processing and flexibility in tube type are required.

Q: What safety features does the centrifuge offer during operation?

A: Safety is ensured by automatic lid locking, imbalance detection that halts operation if imbalance is detected, and an emergency lid release feature. These mechanisms protect both the operator and samples during every run.

Q: How does the non-refrigerated design affect sample processing?

A: Being non-refrigerated, the centrifuge is suitable for protocols where precise temperature control is not critical. It is well-suited for routine separations or pelleting applications involving samples stable at ambient temperatures.

Q: What are the benefits of the Swing-bucket Rotor A-4-62 design?

A: The swing-bucket rotor allows horizontal separation of samples, resulting in more uniform pelleting and capacity for various tube types. This enhances efficiency and ensures high-quality, reproducible results.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical LAB' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.