  • Features High sensitivity and specificity, ready-to-use reagents, suitable for clinical chemistry analyzers
  • Usage Type Single-use, In Vitro Diagnostic
  • Measurement Range Kit dependent; typically 0-200 U/L ADA
  • Shelf Life 12-18 Months (from manufacturing date)
  • Storage Instructions Store at 2-8C, protected from light
  • Function Enzyme Activity Quantification
  • Accuracy High, as per IFU and clinical standard limits
  • Click to View more
X

Mindray Adenosine deaminase Reagent Kits Price And Quantity

Mindray Adenosine deaminase Reagent Kits Product Specifications

  • Yes
  • 12-18 Months (from manufacturing date)
  • Store at 2-8C, protected from light
  • Adenosine deaminase Reagent Kit
  • High, as per IFU and clinical standard limits
  • No
  • Clear to Slightly Yellow Reagent Solution
  • Enzyme Activity Quantification
  • Not Required (Reagent Kit)
  • Standard kit packaging (refer pack for details)
  • Quantitative determination of adenosine deaminase (ADA) in human serum, plasma, or other biological fluids
  • Single-use, In Vitro Diagnostic
  • Diagnostic Grade Chemicals and Reagents
  • High sensitivity and specificity, ready-to-use reagents, suitable for clinical chemistry analyzers
  • New
  • Pack dependent
  • Automated/Manual (For In Vitro Diagnostic Use)
  • Kit dependent; typically 0-200 U/L ADA
  • Enzymatic (Colorimetric) Method
  • IVD Reagent Kit
  • Yes

Product Description

Brand

Mindray

Sample Type

Whole Blood

Pack Size

R1: 317 ml, R2: 1X8 ml, Std: 11 ml

CAT No.

PDIBS200615

Mindray's chemiluminescence immunoassay controls and calibratorsare the original standards with which to evaluate the precision and accuracy of chemiluminescence immunoassay analyzers and ensure qualified results. All of these controls and calibrators are ready to use and have long-term stability.




Precision Diagnostics for ADA Activity

Mindray ADA Reagent Kits deliver accurate and reliable measurements of adenosine deaminase (ADA) activity, aiding in the differential diagnosis and screening of conditions such as tuberculous pleural effusion. With a measurement range that typically spans 0-200 U/L, these kits are vital for diagnostic laboratories seeking precise results.


Compatible With Your Clinical Chemistry Analyzers

Designed to integrate effortlessly with both Mindray semi-automated and automated analyzers, these ADA reagent kits simplify workflow in clinical laboratories. The kits are highly user-friendly, requiring only 10-20 L per test (refer to IFU), and provide straightforward protocols for both manual and automated platforms.


Ready-to-Use and Reliable Chemical Solutions

Each kit features diagnostic grade, single-use reagents, with clear to slightly yellow solutions that ensure high sensitivity and specificity. The inclusion of both a calibrator or standard (where applicable) and comprehensive instructions allows for 2-point or multipoint calibration as per analyzer requirements, ensuring dependable performance.

FAQ's of Mindray Adenosine deaminase Reagent Kits:


Q: How does the Mindray Adenosine Deaminase Reagent Kit measure ADA activity?

A: The kit utilizes an enzymatic (colorimetric) method to quantify ADA activity by detecting the amount of ammonia produced. The resulting color change is measured on Mindray clinical chemistry analyzers, which correlates directly with ADA concentration in the sample.

Q: What clinical applications are recommended for these ADA reagent kits?

A: Mindray ADA Reagent Kits are primarily recommended for screening tuberculous pleural effusion and aiding in the differential diagnosis of serous effusions. They can be used to evaluate ADA activity in serum, plasma, or other biological fluids.

Q: When should these kits be calibrated and how is calibration performed?

A: Calibration should be performed according to the analyzer protocol, either as a 2-point or multipoint procedure. The supplied calibrator/standard makes this process straightforward, ensuring accurate and reproducible results.

Q: Where can these reagent kits be used and who are the main users?

A: These kits are suitable for clinical laboratories, diagnostic centers, and research institutions equipped with Mindray semi-automated or automated analyzers. Main users include clinicians, laboratory technicians, and medical researchers.

Q: What is the correct process for storing and handling the ADA reagent kits?

A: Store the kits at 2-8C, protected from light, to preserve reagent stability. Always refer to the packaging for lot numbers and batch details, and adhere to the instruction manual for proper handling and usage.

Q: What are the primary benefits of choosing the Mindray ADA Reagent Kit?

A: Key benefits include high sensitivity and specificity, compatibility with automated/manual analyzers, ready-to-use reagents, and reliable performance for quantitative ADA determination, all contributing to streamlined diagnostic workflows.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical Reagents' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.