Abbott GRAFTMASTER RX Coronary Stent Graft System (SD 4.0)

Abbott GRAFTMASTER RX Coronary Stent Graft System (SD 4.0)

Product Details:

  • Measurement Range Stent Diameter: 4.0 mm
  • Instruments Type Interventional Cardiology Device
  • Shelf Life Up to 3 years
  • Function Seals coronary artery perforations
  • Usage Type Single use
  • Features Balloon expandable, rapid exchange delivery, covered stent design
  • Storage Instructions Store in original packaging, at controlled room temperature
  • Click to View more
X

Abbott GRAFTMASTER RX Coronary Stent Graft System (SD 4.0) Price And Quantity

Abbott GRAFTMASTER RX Coronary Stent Graft System (SD 4.0) Product Specifications

  • Coronary Stent Graft System
  • Single use
  • Interventional Cardiology Device
  • Stent Diameter: 4.0 mm
  • Transparent/metallic
  • Yes
  • Seals coronary artery perforations
  • Up to 3 years
  • PTFE (Polytetrafluoroethylene) covered stent with stainless steel
  • Yes
  • Manual via catheter delivery system
  • No
  • Balloon expandable, rapid exchange delivery, covered stent design
  • PTFE covered stent on a rapid exchange (RX) balloon dilatation catheter
  • Treatment of coronary artery perforations
  • New
  • Store in original packaging, at controlled room temperature
  • Latex Free
  • 30C
  • 0.014\\
  • Abbott GRAFTMASTER RX (SD 4.0)
  • Yes
  • Coronary artery perforation, saphenous vein graft perforation
  • Sterile EO (Ethylene Oxide)
  • Individually packed, sterile pouch
  • 4.0 mm
  • 16 mm
  • Enhanced with radiopaque markers
  • 15C
  • Rapid Exchange (RX)
  • Cobalt Chromium with expanded PTFE (ePTFE) sleeve
  • 16 atm (Rated Burst Pressure)
  • 6 Fr
  • Semi-Compliant

Product Description

Brand Abbott
Stent Diameter (mm) 4.0
Stent Length (mm) 16, 19, 26, 29
CAT No 1012819-16, 1012819-19, 1012819-26, 1012819-29
Catheter Length 143 cm

The GRAFTMASTER RX Coronary Stent Graft System is indicated for use in the treatment of free perforations, defined as free contrast extravasation into the pericardium, in native coronary vessels or saphenous vein bypass grafts 2.75 mm in diameter. The effectiveness of this device for this use has not been demonstrated. Long-term outcome for this permanent implant is unknown at present.



Rapid Exchange Delivery for Emergency Situations

The GRAFTMASTER RX system is engineered for swift deployment in critical scenarios such as coronary artery perforations. Its rapid exchange catheter platform simplifies handling, allowing for quick insertion and precise positioning. Enhanced with radiopaque markers, clinicians achieve optimal visualization during placement, reducing procedure time and improving patient outcomes.


Advanced Stent Graft Technology

Combining a cobalt chromium stent with a PTFE (ePTFE) sleeve, the device provides robust vessel support and effective perforation sealing. Balloon expandable, it adapts to various lesion characteristics while minimizing the risk of additional damage. The systems compatibility with standard 0.014" guidewires and 6 Fr guide catheters ensures procedural versatility.


Safety and Storage Assurance

Each stent graft is supplied in a sterile, latex-free pouch to protect against contamination. With a shelf life of up to three years under controlled temperatures (15C30C), users can confidently manage inventory for readiness. The device is intended for single use, ensuring maximum patient safety and consistent product quality.

FAQs of Abbott GRAFTMASTER RX Coronary Stent Graft System (SD 4.0):


Q: How is the Abbott GRAFTMASTER RX (SD 4.0) stent graft system used during a procedure?

A: The GRAFTMASTER RX is deployed using a rapid exchange balloon catheter over a 0.014" guidewire. It is inserted into the affected coronary artery via a 6 Fr guide catheter, then manually inflated up to 16 atm to seal the perforation with its PTFE-covered stent.

Q: What are the primary indications for the Abbott GRAFTMASTER RX (SD 4.0)?

A: This system is intended for sealing coronary artery perforations and saphenous vein graft perforations that occur during percutaneous coronary interventions (PCI), providing immediate vessel integrity restoration.

Q: When should the GRAFTMASTER RX (SD 4.0) be selected over other stents?

A: Choose this system when a perforation is detected during coronary or saphenous vein graft interventions, as its covered stent design provides rapid sealing and minimization of further blood loss.

Q: Where can the Abbott GRAFTMASTER RX (SD 4.0) be stored before use?

A: The device should be stored in its original, sterile pouch at a controlled room temperature between 15C and 30C to maintain its three-year shelf life and sterility.

Q: What process ensures the sterility of the GRAFTMASTER RX (SD 4.0)?

A: The device is sterilized using ethylene oxide (EO) and is individually packed in a sterile, latex-free pouch, ensuring it is ready for immediate use upon opening.

Q: What are the benefits of using a PTFE-covered, balloon-expandable stent graft?

A: This design offers both the flexibility for complex vessel anatomy and a reliable seal for vessel perforations. The PTFE cover prevents blood leakage, while balloon expansion enables precise deployment.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical Surgicals' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.