Product Description
| Brand |
FUJIFILM |
| Sample Type |
Serum/ Plasma |
| Pack Size |
24T |
| CAT No |
16094170 |
| Application |
Total carbon dioxide Concentration |
Fujifilm DRI-CHEM SLIDE Colorimetric method slide. Enzymes, General chemistry, and Immunology. This multilayered slide is composed of dry chemical ingredients needed for the reaction and other functional materials. It quantifies enzymes and chemicals using colorimetric method.
1. Applicable only to the analyzers equipped with a 415 nm ?lter (DRI-CHEM NX500, NX700 and 7000).
2. Not applicable to PF function.
Efficient TCO2 Measurement for Clinical LabsDesigned specifically for clinical chemistry applications, the FUJIFILM FUJI DRI-CHEM SLIDE TCO2-P ensures seamless operation with FUJI DRI-CHEM Analyzers. Its easy-to-use, single-use format minimizes handling errors, while barcode labeling ensures efficient sample tracking and workflow integration. With robust dry chemistry technology, laboratories can expect fast, reliable quantitative TCO2 results for improved patient care.
Optimized for Convenience and Workflow IntegrationEach slide is individually packed to ensure freshness and prevent contamination. They are lightweight and portable, fitting easily into clinical workflows. Storage requirements are minimalstore at 2-8C, protected from light and moistureallowing labs to maintain a ready inventory for real-time testing needs.
FAQs of FUJIFILM FUJI DRI-CHEM SLIDE TCO2-P:
Q: How do I use the FUJIFILM FUJI DRI-CHEM SLIDE TCO2-P with my analyzer?
A: Simply load the individually packed TCO2-P slide into a compatible FUJIFILM DRI-CHEM Analyzer (such as NX500, NX600, or NX700), add the required serum or plasma sample (1020 L per slide), and start the automatic testing process as per your analyzers operating instructions.
Q: What types of samples are compatible with the TCO2-P slide?
A: The TCO2-P slide is specifically designed for quantitative measurement of total carbon dioxide in serum or plasma samples. It is not intended for use with whole blood or other sample types.
Q: When should I replace or discard a slide?
A: Each TCO2-P slide is intended for single use only. Discard slides after one test, and ensure unused slides are stored between 2-8C to maintain their 12-24 month shelf life, as specified on the packaging.
Q: Where should the slides be stored to preserve their quality?
A: Slides should be kept in their original packaging, refrigerated at 2-8C, and protected from light and moisture. Proper storage conditions will help maintain their accuracy and reliability throughout their shelf life.
Q: What are the benefits of using individually packed slides with barcode labeling?
A: Individually packed slides ensure sterility, reduce contamination risks, and enable accurate sample tracking through barcode scanning, streamlining laboratory workflow and minimizing identification errors.
Q: How does the dry chemistry technology enhance testing?
A: Dry chemistry eliminates the need for liquid reagents, reducing preparation time and minimizing the risk of reagent handling errors. It offers consistent, reliable results and supports automation with FUJIFILM analyzers.