Product Description
| Brand | Metrohm |
| Material | Glass |
| Capacity | 0-14 pH |
| CAT No | 600470300 |
| Application | Titration Accessories |
Intelligent, combined silver ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data. This maintenance-free electrode is suitable for precipitation titrations when the pH value remains constant (titrant silver nitrate).
Precision Measurement for Argentometric TitrationsDesigned for laboratory professionals, the Metrohm iAg Titrode delivers reliable, fast response in silver ion-selective measurements. Its double-junction Ag/AgCl/KCl system and transparent glass body ensure accurate results in the titration of halides, silver ions, and other analytes.
Broad Instrument CompatibilityThe electrode features a Metrohm plug-head connector with a fixed cable, making it compatible with multiple Metrohm titrators such as OMNIS and Titrino plus series, as well as a variety of other models (862/916/905/907/888/877/899/10XX). This versatility ensures seamless integration into existing laboratory workflows.
Maintenance Made SimpleRoutine electrode care involves cleaning the sensitive glass membrane and refilling the reference chamber with the recommended KCl solution. This straightforward process prolongs electrode lifespan and helps maintain consistently accurate results, contributing to reliable laboratory performance.
FAQ's of Metrohm iAg Titrode:
Q: How is the Metrohm iAg Titrode used in laboratory titrations?
A: The Metrohm iAg Titrode is designed for argentometric titrations, specifically measuring silver content in samples such as halides, cyanides, and mercaptans. It is typically connected to a compatible Metrohm titrator, allowing automatic or manual titration for precise laboratory analysis.
Q: What maintenance procedures should be followed for optimal performance?
A: Routine maintenance includes regular cleaning of the glass membrane and refilling the reference chamber with c(KCl) = 3 mol/L solution. This helps prevent contamination and ensures reliable, fast response times during measurements.
Q: When should the electrode be refilled and cleaned?
A: The reference chamber should be refilled if the KCl level drops below the recommended level or after prolonged use, while the glass membrane should be cleaned whenever there is evidence of fouling or prior to critical measurement tasks for best results.
Q: Where should the Metrohm iAg Titrode be stored to maintain its longevity?
A: The electrode should be stored in a KCl solution or according to Metrohm's manufacturer instructions. Proper storage prevents the reference electrolyte from drying out and maintains the electrode's responsiveness.
Q: What are the principal benefits of using this titration electrode?
A: The iAg Titrode offers rapid response, high selectivity for silver ions, and robust compatibility with major Metrohm titration systems. These features ensure accurate measurements essential for research, quality control, and process monitoring in laboratories.
Q: How does the electrode connect to titration instruments?
A: It utilizes a Metrohm plug-head with a fixed cable, enabling easy and secure connection to supported Metrohm titrators such as the OMNIS and Titrino plus series, guaranteeing straightforward setup and operation.
Q: What solutions and conditions are required for measurement and storage?
A: Fill the electrode's reference system with c(KCl) = 3 mol/L solution and operate within the 0 to 40C temperature range. For storage, immerse the electrode in KCl solution or follow Metrohm's guidelines to ensure optimal functionality.