Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS    Call Me Free
Eppendorf Biospectrometer Basic.

Eppendorf Biospectrometer Basic.

Product Details:

  • Power AC adapter
  • Capacity Single sample cuvette
  • Material Plastic and metal housing
  • Application Life science laboratories, Biotechnology, Clinical diagnostics
  • Usage For measurements in the UV/Vis wavelength range
  • Operate Method Touchscreen with intuitive software interface
  • Weight 3.7 kg
  • Click to View more
X

Eppendorf Biospectrometer Basic. Price And Quantity

Eppendorf Biospectrometer Basic. Product Specifications

  • 3.7 kg
  • 100240 V, 5060 Hz
  • White / Blue interface
  • Single sample cuvette
  • AC adapter
  • Life science laboratories, Biotechnology, Clinical diagnostics
  • Plastic and metal housing
  • For measurements in the UV/Vis wavelength range
  • Touchscreen with intuitive software interface
  • Basic model
  • Biospectrometer
  • 230 mm x 320 mm x 100 mm

Product Description

Brand Eppendorf
Wavelength Range 200-830 nm
Cat No 6135000002

 Eppendorf BioSpectrometer basic shares its simplicity, flexibility and reliability. In addition to the Biophotometer D30, the Biospectrometer basic has freely selectable wavelengths from 200 830 nm (selectable in 1 nm increments). This allows the user to define the parameters of each assay, whether it be a scan, a single-wavelength measurement or a multi-wavelength measurement. The Eppendorf BioSpectrometer basic caters to more disciplines as the wavelengths are not pre-defined and allows for non-routine assays or new assays to be easily programmed (in addition to the pre-programmed routine methods). The Eppendorf BioSpectrometer basic is a robust yet flexible  workhorse.



Precision UV/Vis Measurements for Your Laboratory

The Eppendorf Biospectrometer Basic ensures reliable and accurate measurements across the UV/Vis spectrum. Enhanced with a photometric range of 0.2-2.5 Abs and high accuracy, it caters to essential laboratory workflows, including nucleic acid, protein quantification, and cell density measurements. Its advanced xenon flash lamp technology and robust design offer stable, reproducible results, indispensable for research and routine testing.


User-Friendly Operation and Flexibility

Featuring an intuitive color touchscreen and embedded control software, the Biospectrometer Basic simplifies the user experience. Quick navigation and clearly structured menus streamline experimental setups. The instrument accommodates both standard and micro-volume cuvettes, supports single sample measurements, and stores or exports data via a convenient USB port, ensuring flexibility and efficiency for busy laboratory environments.

FAQ's of Eppendorf Biospectrometer Basic.:


Q: How do I export measurement data from the Eppendorf Biospectrometer Basic?

A: You can export measurement data easily via the built-in USB port. Insert a compatible USB storage device into the port and follow the prompts on the intuitive touchscreen to save your results for further analysis or record keeping.

Q: What applications can the Biospectrometer Basic support in my laboratory?

A: This spectrophotometer is designed for quantifying DNA, RNA, and proteins, measuring optical density at 600 nm (OD600), conducting kinetic assays, and implementing custom protocols. It serves life science, biotechnology, and clinical diagnostics laboratories needing UV/Vis analysis.

Q: Where can I use the Eppendorf Biospectrometer Basic within my workflow?

A: The instrument can be integrated wherever precise UV/Vis absorbance measurements are required, from research labs performing nucleic acid quantification to routine sample analysis in biotechnology or diagnostic environments.

Q: What types of cuvettes are compatible with the instrument?

A: The Biospectrometer Basic supports both standard and micro-volume cuvettes. Its flexible cuvette holder accommodates various sample volumes, providing adaptability for different assay requirements.

Q: When should I calibrate or verify the instrument's performance?

A: It is recommended to perform periodic performance verification following laboratory protocols or after moving the instrument. Calibration standards compatible with UV/Vis measurements can be used to confirm accuracy and precision.

Q: How does operating temperature affect performance?

A: The instrument is designed to operate reliably within an ambient temperature range of 15-35 C. Staying within these limits ensures accurate results and optimal performance of the xenon flash lamp and optical system.

Q: What benefits does the embedded software interface provide?

A: The embedded software offers a user-friendly experience through its touchscreen interface, allowing quick setup, method selection, and data management. This minimizes training time and enhances workflow efficiency.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical LAB' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.