Product Description
Brand Mindray
Sample Type Serum
Pack Size 2 x 50T, 2 x 100T
CAT No 10500421000, 10500423700
Application Immuno-Assay
Ourchemiluminescence immunoassay reagentshave been specially developed to work with Mindray's CL series automatic chemiluminescence immunoassay analyzers to make a complete system, offering high reliability and accuracy. Mindray uses liquid, ready-to-use reagents which come in two packages, 50 tests and 100 tests, to suit customers with different requirements.
Advanced CLIA TechnologyLeveraging chemiluminescence immunoassay (CLIA) technology, this Mindray kit ensures high sensitivity and specificity in total T3 measurement. This modern approach supports accurate diagnostic workflows for thyroid function assessment, making it suitable for clinical laboratories aiming for dependable and reproducible results.
Comprehensive, Ready-to-Use FormatThe kit arrives fully equipped with all essential components: two specialized reagents, calibrators, and clear instructions. Its user-friendly, ready-to-use configuration streamlines laboratory operations and minimizes preparation errors, supporting consistent high-volume testing. Calibration and lot traceability are provided by the manufacturer for quality assurance.
Optimized for Mindray AnalyzersDesigned specifically for Mindray CL-1000i, CL-2000i, and CL-900i platforms, this kit ensures seamless compatibility and efficient integration into automated immunoassay workflows. The precise reagent formulation allows quick assay completion, typically within 30 minutes, enabling labs to maintain high throughput without compromising result integrity.
FAQ's of Mindray Total Triiodothyronine (CLIA):
Q: How does the Mindray Total Triiodothyronine (CLIA) Kit work?
A: This kit utilizes a two-step competitive chemiluminescence immunoassay (CLIA) method to detect and quantify total T3 hormone in human serum. The process involves a reaction between the sample and reagents, producing a chemiluminescent signal proportional to the T3 level.
Q: What components are included in the Mindray Total T3 Kit package?
A: The kit contains Reagent 1 (R1), Reagent 2 (R2), calibrators for assay calibration, and detailed instructions for use. All components are ready-to-use, ensuring a streamlined laboratory workflow.
Q: When should laboratories consider using this kit?
A: It is ideal for routine and specialized thyroid function testing where rapid, accurate quantification of total T3 is required-particularly in automated laboratory environments utilizing compatible Mindray analyzers.
Q: Where can the Mindray Total T3 (CLIA) Kit be used?
A: This kit is intended for professional use in clinical laboratory settings equipped with Mindray CL-1000i, CL-2000i, or CL-900i immunoassay analyzers.
Q: What is the proper storage condition for this reagent kit?
A: Store the kit components at 2-8C. Do not freeze. This ensures stability and maintains the stated shelf life of 12 months as per manufacturer recommendations.
Q: How is the assay process conducted using this kit?
A: After loading the kit components into a compatible Mindray analyzer, follow the on-screen instructions. The instrument automates the process, delivering results within approximately 30 minutes.
Q: What are the main benefits of using this reagent kit in the laboratory?
A: Key benefits include accurate and reliable T3 quantification, high throughput capability, compatibility with Mindray CL analyzers, and ease of use due to its ready-to-use format and minimal preparation requirements.