Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS    Call Me Free
Metrohm KF Adsorber Tube for Coulometer Cell Metrohm KF Adsorber Tube for Coulometer Cell Metrohm KF Adsorber Tube for Coulometer Cell
Metrohm KF Adsorber Tube for Coulometer Cell
Metrohm KF Adsorber Tube for Coulometer Cell Metrohm KF Adsorber Tube for Coulometer Cell

Metrohm KF Adsorber Tube for Coulometer Cell

Product Details:

  • Material Glass tube with desiccant (molecular sieve or silica gel)
  • Capacity Standard moisture capacity for extended KF titration use
  • Classification Laboratory Accessory
  • Color Transparent with blue and white end caps
  • Operate Method Insert into cell inlet/outlet port; passive adsorption
  • Dimension (L*W*H) Approx. 120 mm (Length) 18 mm (Diameter)
  • Application Metrohm Karl Fischer Coulometric Titration Systems
  • Click to View more
X

Metrohm KF Adsorber Tube for Coulometer Cell Price And Quantity

  • Depends on frequency of use and exposure
  • Efficient water vapor adsorption to protect reagent longevity
  • Meets Metrohm OEM standards
  • Yes, with desiccant replacement
  • Metrohm 831, 832, 851, and other related KF Coulometers
  • Rubber and PTFE stopper
  • Re-fillable and replaceable drying agent
  • Metrohm 6.2803.070 or equivalent
  • 5°C to 40°C

Metrohm KF Adsorber Tube for Coulometer Cell Product Specifications

  • Glass tube with desiccant (molecular sieve or silica gel)
  • To adsorb moisture and prevent ingress of water vapor in Karl Fischer (KF) Coulometer Cell
  • Laboratory Accessory
  • Standard moisture capacity for extended KF titration use
  • Approx. 35 grams
  • KF Adsorber Tube
  • Insert into cell inlet/outlet port; passive adsorption
  • Transparent with blue and white end caps
  • Approx. 120 mm (Length) 18 mm (Diameter)
  • Metrohm Karl Fischer Coulometric Titration Systems
  • Depends on frequency of use and exposure
  • Efficient water vapor adsorption to protect reagent longevity
  • Meets Metrohm OEM standards
  • Yes, with desiccant replacement
  • Metrohm 831, 832, 851, and other related KF Coulometers
  • Rubber and PTFE stopper
  • Re-fillable and replaceable drying agent
  • Metrohm 6.2803.070 or equivalent
  • 5°C to 40°C

Product Description



Discover a sizzling solution for Karl Fischer titration with the Metrohm KF Adsorber Tube, featured for its extraordinary moisture retention and exceptional efficiency. Designed for use with Metrohm 831, 832, 851, and compatible KF Coulometers, this sterling laboratory accessory utilizes a refillable desiccant and durable glass body for reliable, extended use. Its rubber and PTFE stopper ensures seamless insertion, while efficient water vapor adsorption protects reagent longevity. Reusable and OEM compliant, it offers transparent design with blue and white end caps and supports optimal results in precise titration environments across India.

Key Features and Applications

The Metrohm KF Adsorber Tube is used for adsorbing moisture and preventing water vapor ingress in Karl Fischer (KF) Coulometric Titration Cells. It is commonly used by laboratory professionals and research chemists for accurate moisture analysis. Constructed from robust glass with a replaceable desiccant, it ensures sustained performance and excellent transparency for visual monitoring. This product is especially suited for instruments requiring precise environmental control to maintain reagent efficacy, notably within Metrohm's acclaimed range.


Availability and Certifications in the Indian Market

Stock ready and available across the main domestic market of India, the Metrohm KF Adsorber Tube is supported by complete certifications as per Metrohm OEM standards. Place your order for prompt order completion and competitive FOB port pricing. Obtain a quotation from authorized dealers, distributors, exporters, manufacturers, suppliers, traders, and wholesalers. With strict quality benchmarks, you can trust reliable delivery and compliance for every laboratory need.


FAQ's of Metrohm KF Adsorber Tube for Coulometer Cell:


Q: How is the Metrohm KF Adsorber Tube installed in a KF Coulometer cell?

A: Insert the Adsorber Tube into the cell's inlet or outlet port, where it passively adsorbs moisture to protect the reagent.

Q: What is the benefit of using a refillable and replaceable desiccant in the Adsorber Tube?

A: A refillable and replaceable desiccant allows prolonged use of the tube, ensuring effective moisture adsorption over extended periods and reducing overall replacement costs.

Q: When should the desiccant be replaced in the Metrohm KF Adsorber Tube?

A: Replace the desiccant when you notice decreased adsorption efficiency or after significant exposure to moisture, depending on frequency of use.

Q: What materials make up the Metrohm KF Adsorber Tube?

A: It consists of a transparent glass tube filled with either molecular sieve or silica gel, and features rubber and PTFE stoppers.

Q: Where can I purchase the Metrohm KF Adsorber Tube in India?

A: The tube is available through authorized dealers, distributors, exporters, manufacturers, suppliers, traders, and wholesalers across India.

Q: How does the Adsorber Tube enhance the longevity of Karl Fischer reagents?

A: By efficiently adsorbing water vapor from the cell environment, it prevents moisture ingress, safeguarding the reagent's stability and accuracy of results.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical LAB' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.