Contact UsCompany ProfileHome
Saaskin Technologies
Send Inquiry Send SMS    Call Me Free
Mettler Toledo Spectrophotometer Easy VIS ScanStart Mettler Toledo Spectrophotometer Easy VIS ScanStart Mettler Toledo Spectrophotometer Easy VIS ScanStart
Mettler Toledo Spectrophotometer Easy VIS ScanStart
Mettler Toledo Spectrophotometer Easy VIS ScanStart Mettler Toledo Spectrophotometer Easy VIS ScanStart

Mettler Toledo Spectrophotometer Easy VIS ScanStart

Product Details:

  • Capacity Single cell, cuvette, and round cell measurements
  • Voltage 100 - 240 V AC
  • Color White & Blue
  • Classification Easy VIS ScanStart
  • Power 30 W
  • Operate Method Touch Screen, USB Interface
  • Material NEW
  • Click to View more
X

Mettler Toledo Spectrophotometer Easy VIS ScanStart Price And Quantity

  • 1 Unit

Mettler Toledo Spectrophotometer Easy VIS ScanStart Product Specifications

  • 365 mm x 272 mm x 115 mm
  • NEW
  • Laboratories, Food & Beverage, Water Analysis, Environmental Testing
  • Approx. 4.5 kg
  • Instrument
  • Laboratory
  • Single cell, cuvette, and round cell measurements
  • 100 - 240 V AC
  • Easy VIS ScanStart
  • White & Blue
  • Touch Screen, USB Interface
  • 30 W
  • USB, Ethernet
  • Internal storage for methods and results
  • Transmittance, Absorbance, Concentration
  • Tungsten halogen lamp
  • 320 nm - 1100 nm
  • 4-position automaticchanger
  • Large color touchscreen
  • Silicon photodiode
  • Automatic wavelength calibration
  • 4 nm

Product Description

Easy VIS provides an economic option for the spectrophotometric analysis using visible light. Together with the handheld barcode scanner, the ScanStartâ„¢ function offers convenient method handling, e.g., for using water test kits.

Brand Mettler Toledo
Capacity 330 nm - 1,000 nm
Model 30997810
CAT No. Refer Below



Advanced Measurement Versatility

The Easy VIS ScanStart offers multiple measurement modes, including transmittance, absorbance, and concentration, accommodating single cell, cuvette, and round cell formats with a 4-position automatic changer. This flexibility makes it suitable for diverse laboratory applications.


Intuitive Touchscreen Control

Equipped with a large color touchscreen display, the spectrophotometer delivers effortless operation and streamlined navigation. Users can easily access stored methods, review results, and configure settings, making routine and advanced experiments straightforward.


Reliable Performance and Storage

Offering internal storage for both methods and results, the Easy VIS ScanStart safeguards valuable data. Automatic wavelength calibration and stable 30 W power ensure consistent accuracy, while versatile connectivity (USB, Ethernet) allows seamless data transfer and remote management.

FAQ's of Spectrophotometer Easy VIS ScanStart:


Q: How does the Easy VIS ScanStart facilitate routine laboratory analysis?

A: With automatic wavelength calibration and a user-friendly touchscreen, the Easy VIS ScanStart simplifies setup and operation. Its internal storage saves protocols and results, reducing manual entry and improving workflow for everyday laboratory tasks.

Q: What types of samples and cuvettes are compatible with this spectrophotometer?

A: The Easy VIS ScanStart supports single cell, cuvette, and round cell sample measurements, and is equipped with a 4-position automatic cuvette changer. This allows flexible handling of various sample types for different analytical tasks.

Q: When should the automatic wavelength calibration feature be used?

A: Automatic wavelength calibration should be performed at instrument startup or when high-precision measurements are required. This ensures the spectrophotometer maintains optimal accuracy over its wavelength range of 320 nm to 1100 nm.

Q: Where can the Easy VIS ScanStart be used, and who is it designed for?

A: The device is ideal for laboratories engaged in food & beverage testing, water analysis, or environmental studies. It is suited for dealer, distributor, exporter, manufacturer, supplier, trader, and wholesaler operations across India.

Q: What is the process for saving and retrieving measurement methods and results?

A: Users can store methods and measurement results directly on the internal memory via the touchscreen interface. Retrieval is simple and can be exported using USB or Ethernet connectivity for further analysis or documentation.

Q: How does this instrument benefit multi-user laboratories?

A: With robust internal storage, a large display, and intuitive operation, the Easy VIS ScanStart allows multiple users to access, save, and share methods and results efficiently, promoting collaborative work and reducing errors in busy laboratory environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical LAB' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.